Installation

Gas Supply

Gas Connection

Figure 2.4

Gas Connection - End View (shown installed from above)

Drip leg / Sediment trap
(field supplied)

Elbow

Shut off valve /
inlet tap
(field supplied)

Ground
joint union

Tee

Elbow

Shut off valve/

inlet tap
(field supplied)

Elbow

Ground

joint union

NOTE: Do not exceed 14 inches W.C. to the
appliance. Use a regulator when gas supply
pressure exceeds 14 inches W.C.

Figure 2.5

Gas Connection - End View (shown installed from below)

WARNING

!

!

Failure to disconnect the electricity to the heater before disconnecting the gas supply
may result in explosion, fire, property damage, injury or death.

To disconnect the gas:

1

Disconnect the power to the heater.

2

Turn off the gas supply to the heater and ”bleed” the gas line.

3

Using two wrenches, slowly loosen the fittings. Excessive torque on the manifold may misalign the

orifice.

4

Inspect the gas pipe. Replace if necessary.

5

Always cap off and leak check any open gas lines that are not in use.