Appendix A - Maintenance

Maintenance Procedures

The following maintenance procedures should be performed on a routine basis:

1.

Drain the unit’s fuel reservoirs and replace the fuel filters after every 30 cleaning services for
Gasoline (Petrol), or every 10 cleaning services for the unit’s diesel fuel reservoir for
maximum performance as described in the next section.

2.

Clean the exterior with a non-abrasive cleaning agent or similar product to keep the cabinet
looking new. Check the cabinet for dents or impact markings.

3.

Check all hoses and wires for cuts or frays.

Replacing the MCS 352 Fuel Filters

The unit’s gasoline (petrol) fuel reservoir should be drained and the fuel filter replaced after
every 30 cleanings to ensure maximum system performance and pump life. The unit’s diesel
fuel reservoir should be drained and the fuel filter replaced every 10 cleanings for maximum
performance.

Drain the Fuel Reservoir

1.

Turn

the

SERVICE SELECTOR

switch to either

Gasoline (Petrol) or Diesel FUEL SYSTEM.

2.

On the

Gasoline (Petrol)

side, turn the

PRESSURE REGULATOR

on the control panel

clockwise until it is completely closed.

3.

Attach the unit to the vehicle's battery by connecting the

red

battery clip to the positive (

+

)

battery terminal and the

black

battery clip to a solid ground point as far from the battery as

possible. Turn on the

ON/OFF

switch.

4.

Connect the #060-1400 adaptor to the output (

red

) hose, then drain the fuel from the

unit’s fuel reservoir using the following procedure:

x Set the

TIMER

until it displays five minutes.

x Direct the output (

red

) hose into an appropriate container.

x Press and hold the

START/RUN

switch until the fuel from the unit has been emptied into

the container.

x Release the

START/RUN

switch.

x On the

Gasoline (Petrol)

side, turn the

PRESSURE REGULATOR

counterclockwise until

completely open to relieve any residual pressure.

5.

Enter your initials, the date, and a check mark in the appropriate boxes of the Maintenance
Record at the end of this chapter.