11.
The unit will automatically shut off and the alarm will sound when the engine is
stopped. Press off the
ON/OFF
switch.
12.
Turn
the
Gasoline (Petrol) PRESSURE REGULATOR
counterclockwise on the unit
to release residual pressure.
IMPORTANT
Wrap a shop towel around pressure fittings
before disconnection to protect against
residual fuel spray.
13.
Disconnect the battery leads, hoses, and adaptors. Return the vehicle's fuel system to
its normal operating condition by re-connecting the vehicle's fuel lines.
14.
Re-install the vehicle's gas cap.
15.
Start the vehicle
and verify that there are no leaks.
16.
Test drive the vehicle for five kilometers (3 miles) immediately following the
cleaning service to flush all detergent from the vehicle's fuel and exhaust systems.