background image

200-8241 REV. 2

17

DieselTune 4000 Operators Manual

6.

If the

REVERSE POLARITY LED

illuminates then battery connections are incorrect,

reconnect leads properly. The

FUEL LEVEL

Display LEDs should be illuminated and display

the fuel level.

NOTE

If nothing appears on the display, check that the battery clips are attached to the
proper terminals on the battery (BLACK clip to ground connection, RED clip to
positive terminal). If the battery clips are connected correctly, check the condition
of the vehicle’s battery.

7.

Press and release the

FILL button

to begin the

FILL mode

process.

8.

When the unit reaches the Full level in the tank the pump will stop filling automatically. If using

less than a full tank, press and release the

STOP

button to stop the filling process.


NOTE

The DOWN ARROW LED will appear steady on the display,
as fuel is pumped from the vehicle’s tank to the units tank.
One LED (1/8 tank increments) corresponds to 5/16ths of a
gallon (40 oz., 1.2L) will appear on the system’s fuel gauge
display.




IMPORTANT

When mixing the cleaner in an external container,
measure equal parts cleaner and fuel in a suitable
container. Keep container sealed when not in use.


1.

Remove the

OUT/FILL (RED)

hose from the fuel source container, and using a shop cloth to catch

any spills, remove the Fill adapter.

Purging Air from the System (Priming)

It will be necessary to purge the air from the unit’s plumbing prior to connecting to the engine’s fuel

system.

1.

Connect the

OUT/FILL (RED)

hose and the

RETURN (BLACK)

hose to each end of

PRIME

adaptor

(MV P/N 060-4700), as shown in

FIGURE A

.