DieselTune 4000 Operators Manual
6.
If the
REVERSE POLARITY LED
illuminates then battery connections are incorrect,
reconnect leads properly. The
FUEL LEVEL
Display LEDs should be illuminated and display
the fuel level.
NOTE
If nothing appears on the display, check that the battery clips are attached to the
proper terminals on the battery (BLACK clip to ground connection, RED clip to
positive terminal). If the battery clips are connected correctly, check the condition
of the vehicle’s battery.
7.
Press and release the
FILL button
to begin the
FILL mode
process.
8.
When the unit reaches the Full level in the tank the pump will stop filling automatically. If using
less than a full tank, press and release the
STOP
button to stop the filling process.
NOTE
The DOWN ARROW LED will appear steady on the display,
as fuel is pumped from the vehicle’s tank to the units tank.
One LED (1/8 tank increments) corresponds to 5/16ths of a
gallon (40 oz., 1.2L) will appear on the system’s fuel gauge
display.
IMPORTANT
When mixing the cleaner in an external container,
measure equal parts cleaner and fuel in a suitable
container. Keep container sealed when not in use.
1.
Remove the
OUT/FILL (RED)
hose from the fuel source container, and using a shop cloth to catch
any spills, remove the Fill adapter.
Purging Air from the System (Priming)
It will be necessary to purge the air from the unit’s plumbing prior to connecting to the engine’s fuel
system.
1.
Connect the
OUT/FILL (RED)
hose and the
RETURN (BLACK)
hose to each end of
PRIME
adaptor
(MV P/N 060-4700), as shown in
FIGURE A
.