HRC FUSE RECOMMENDED
MAINS VOLTAGE AT SITE
MS 6152 MS 6202
220 VOLTS 3 PHASE 60 AMPS
70 AMPS
380 VOLTS 3 PHASE 40AMPS
50 AMPS
415 VOLTS 3 PHASE
30 AMPS
40 AMPS
460 VOLTS 3 PHASE
30 AMPS
40 AMPS
TROUBLE GUIDE CAUSE REMEDY
1.FUSES BLOWN. 1.REPLACE FUSES
2.CABLE DAMAGED 2.SHORTEN/REPLACE CABLE
PUMP DOES NOT START
3.NO POWER. 3.CHECK POWER SUPPLY
4.BLOCKED IMPELLER. 4.CLEAN BOTTOM PARTS.
5.STATOR WINDING BURNT. 5.REPLACE STATOR.
1.BLOCKED IMPELLER. 1.CLEAN BOTTOM PARTS.
2.IMPELLER ROT.WRONG 2.SHIFT TWO PHASE CONN.
PUMP STARTS BUT STOPS
. 3.CONNECTED FOR WRONG 3.CHECK & RECONNECT.
VOLTAGE.
4.VOLTAGE TOO LOW/HIGH. 4.APPROACH POWER CO.
5.LIQUID DENSITY HIGH 5.HIGHER HP REQUIRED.
6.BI-METAL TRIPS. 6.CHECK CURRENT.
1.IMPELLER ROT.BACKWARD. 1.SHIFT TWO PHASE CONN.
2.PUMP WORN DOWN. 2.REPLACE IMPELLER.
PUMP GIVES TOO LITTLE
3.LONG HOSE AND DIAMETER 3.CHECK PRESSURE LOSSES
WATER.
TOO SMALL.
4.PRESSURE HEAD TOO HIGH 4.INSTALL BIGGER PUMP.
5.WEARING RING WORN OUT. 5.REPLACE WEAR RING.