Hrc fuse recommended – Mody Pumps MS 6202 User Manual

Page 5

background image

HRC FUSE RECOMMENDED

MAINS VOLTAGE AT SITE

MS 6152 MS 6202

220 VOLTS 3 PHASE 60 AMPS

70 AMPS

380 VOLTS 3 PHASE 40AMPS

50 AMPS

415 VOLTS 3 PHASE

30 AMPS

40 AMPS

460 VOLTS 3 PHASE

30 AMPS

40 AMPS

TROUBLE GUIDE CAUSE REMEDY

1.FUSES BLOWN. 1.REPLACE FUSES

2.CABLE DAMAGED 2.SHORTEN/REPLACE CABLE

PUMP DOES NOT START

3.NO POWER. 3.CHECK POWER SUPPLY

4.BLOCKED IMPELLER. 4.CLEAN BOTTOM PARTS.

5.STATOR WINDING BURNT. 5.REPLACE STATOR.


1.BLOCKED IMPELLER. 1.CLEAN BOTTOM PARTS.

2.IMPELLER ROT.WRONG 2.SHIFT TWO PHASE CONN.

PUMP STARTS BUT STOPS

. 3.CONNECTED FOR WRONG 3.CHECK & RECONNECT.

VOLTAGE.

4.VOLTAGE TOO LOW/HIGH. 4.APPROACH POWER CO.

5.LIQUID DENSITY HIGH 5.HIGHER HP REQUIRED.

6.BI-METAL TRIPS. 6.CHECK CURRENT.


1.IMPELLER ROT.BACKWARD. 1.SHIFT TWO PHASE CONN.

2.PUMP WORN DOWN. 2.REPLACE IMPELLER.

PUMP GIVES TOO LITTLE

3.LONG HOSE AND DIAMETER 3.CHECK PRESSURE LOSSES

WATER.

TOO SMALL.

4.PRESSURE HEAD TOO HIGH 4.INSTALL BIGGER PUMP.

5.WEARING RING WORN OUT. 5.REPLACE WEAR RING.