beautypg.com

Design parameters, Installation – Mody Pumps MS 6202 User Manual

Page 4

background image



G] ELECTRICAL INFORMATION
: MOTORS ARE DESIGNED TO OPERATE ON SINGLE VOLTAGE

AND FREQUENCY. MAXIMUM DEVIATION IN VOLTAGE ALLOWED IS -/+ 6% AND FREQUENCY -/+

3%. CHECK NAME PLATE FOR OPERATING VOLTAGE AND FREQUENCY.


DESIGN PARAMETERS :

LOWEST LIQUID LEVEL SHOULD BE 0.2 MTRS (8”) ABOVE PUMP CASING.

THE MAXIMUM SUBMERGENCE RECCOMENDED IS 15 METRES.(50’)
THE SPECIFIC GRAVITY OF THE PUMPED FLUID SHOULD NOT EXCEED 1.1.

MAXIMUM FLUID TEMPERATURE IS 40 DEG. CELSUIS.
pH OF THE PUMPED FLUID : 6 - 11


INSTALLATION
.

PUMPS ARE AVAIABLE FOR THREE TYPES OF INSTALLATION:

P TYPE INSTALLATION: SEMI PERMANENT/WET. PUMPS ARE LOWERED DOWN GUIDE BARS TO

AUTOMATICALLY CONNECT TO DISCHARGE PIPING. PLEASE SEE ILLUSTRATION AT END OF

MANUAL FOR DETAIL DIMENSIONS AND INSTALLATION.

S TYPE INSTALLATION: PORTABLE/WET. VERSATILE, MULTIPURPOSE, EASY TO INSTALL AND

MOVE FROM SUMP TO SUMP. PUMP IS AVAILABLE WITH HOSE/FLANGE TYPE OUTLET

CONNECTION AND INDEPENDENT BASE STAND. SEE ILLUSTRATION AT END OF MANUAL.


D TYPE INSTALLATION:
THIS IS A DRY WELL INSTALLATION OR IN LINE PUMPING

SYSTEMS. FLANGED CONNECTION TO FIXED SUCTION AND DELIVERY PIPELINES. SUITABLE

FOR HORIZONTAL OR VERTICAL MOUNTING FOR DRY INSTALLATIONS. POWER LIMITATIONS

EXIST FOR CERTAIN MODELS AND EXTERNAL COOLING MAY BE NECESSARY. PLEASE CONTACT

FACTORY/SALES IF PUMP IS TO BE USED WITH THIS TYPE OF INSTALLATION.

• CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP.

• CHECK THAT FUSES ARE INTACT.

• USE SHORTEST POSSIBLE HOSE OF RECOMMENDED DIMENSION. AVOID SHARP BENDS,

CREASES AND CONTRACTIONS. FOR P TYPE AND D TYPE INSTALLATIONS ENSURE ALL

ACCESSORIES ARE AVAILABLE BEFORE STARTING INSTALLATION.

• NEVER LIFT OR PULL THE PUMP BY MEANS OF THE CABLE. SUSPEND THE PUMP BY A

ROPE/CHAIN OR PREFERABLY PLACE IT ON A SOLID BASE. FOR P TYPE INSTALLATIONS

THE REQUISITE CHAIN & TACKLE EQUIPMENT MUST BE AVAILABLE. PLEASE READ OUR

PUBLICATION REGARDING “P” TYPE INSTALLATION.

• WIRE THE PUMP TO THE MAINS CORRECTLY. ALWAYS USE A STARTER OR A PANEL BOARD.

SEE INSTRUCTIONS UNDER "MOTOR PROTECTION" BELOW.

• WHEN THE PUMP IS ENERGIZED IT WILL KICK, WHICH IS OPPOSITE TO THE DIRECTION

OF ROTATION OF THE IMPELLER. SHIFT TWO PHASES IN THE POWER CONNECTION IF THE

KICK IS IN THE WRONG DIRECTION. THE CORRECT DIRECTION IS INDICATED ON THE

PUMP COVER AT THE TOP OF THE PUMP.

• CHECK LEVEL AND CONDITION OF THE OIL AT SERVICE EVERY SIX MONTHS. IF THE OIL

IS EMULSIFIED BY WATER THE SEALS MUST BE REMOVED FROM THE ROTOR SHAFT FOR

FURTHER ACTION. THE SHAFT SEAL SHOULD BE CHECKED FOR WEAR EVERY 2500 HRS. OF

OPERATION. IF SEAL FACES SHOW ANY SIGNS OF WEAR, THEY SHOULD BE REPLACED.

This manual is related to the following products: