Current Unit Indication –

Displays current unit of

measure. Available units of

measure include PSI, Bar, or

kPa. Current unit of measure

is maintained when unit is

cycled off and on.

Current Pressure Indication –

Displays the maximum com-

pression value for the indicated

cylinder until the Pressure Relief

Button is pressed. This is the

measurement of the residual

pressure maintained in the hose

assembly by the Schrader valve.

Cylinder # Indication – Dis-

plays cylinder number related

to current and maximum com-

pression values being dis-

played. Number is advanced

by pressing the Cylinder Button

Maximum Com-

pression Indication

- Displays maximum

compression value for

the indicated cylin-

der. Holds the value

until the Clear Button

is pressed. Value is

stored electronically.

Clear Button

- Clears maximum

compression value

shown for indicated

cylinder. Clears

values for all cylin-

ders and returns to

cylinder 1 if held for

3 seconds.

Pressure Relief Button

Pressing this button relieves

the residual pressure in the tes-

ter hose assembly. The value

indicated for the Current Pres-

sure will return to zero, but the

Maximum Compression value

will be maintained electronically

until the Clear Button is pressed.

Cylinder Advance Button

Pressing this button advanc-

es the cylinder number by one.

If the pressure in the hose as-

sembly is not relieved by press-

ing the Pressure Relief Button

or disconnecting the hose at

the quick disconnect junction,

the values for current max and

stored max for the new cylinder

will reflect the stored hose pres-

sure.

On/Unit/Off Button

Pressing this button

when unit is off, turns

unit on. Pressing and

releasing this button

while the unit is on, ad-

vances the current unit

of measurement forward.

Pressing and holding

this button for 3 seconds

while unit is on, turns

unit off. Tester automati-

cally shuts off after six

(6) minutes of non-use.

Compression values are

maintained when unit is

cycled off and on.