beautypg.com

Minuteman H-BOX 200 User Manual

Page 7

background image

 

 

Parts and Instruction Manual

7

Machine Maintenance

Follow the maintenance schedule to keep the 
machine in good working condition. 

FOR SAFETY: When servicing the machine, unplug 
the power cord(s) from wall outlet(s). 

Daily 

1. Empty and thoroughly rinse out both the 

solution and recovery tanks. 

2. Wipe off the power cord(s) and inspect for 

damage. Repair or replace as necessary. 

3. Coil the cord(s) neatly after use. 
4. Clean the exterior of the machine with an all‐ 

purpose cleaner and a damp cloth. Protect the 
exterior with an automobile interior polish. 

Weekly 

(or after approximately 20 hours of use)

 

1. Flush the solution system with a diluted 

descaler to dissolve normal chemical build‐up: 
a. Pour 2 gallons of warm water (less than 

120 °F/ 49 °C) into the solution tank and 
add diluted descaler (dilute according to 
mixing instructions on the chemical 
package). 

b. Turn on the heater (on machines with a 

built‐in heater). 

c. Turn on the pump and spray through the 

cleaning tool for 1 minute. 
NOTE: 
hard water or chemical deposits 
that break up during descaling may 
become trapped at the spray tips.  It is best 
to remove the spray tips from the tool and 
let them soak in the diluted descaler. 

d. Turn off the heater and turn off the pump. 

Allow the chemical to sit in the machine for 
2 hours. 

2. Inspect the vacuum hose for holes and loose 

hose cuffs. 

 
 

 

 

 

 

 

 

3. Inspect the spray pattern for clogged spray 

tips. If the tips are clogged, remove them and 
soak them in white vinegar for a few hours. 
Wash them out, but never push anything into 
the orifice in the spray tip to unblock it; the 
hole can become enlarged which would 
require replacement. 

4. Inspect the solution hose and quick 

disconnects for leaks or damage. Lubricate the 
QDs with an all‐purpose, water‐resistant 
lubricant. 

5. Lubricate the wheels and casters with an all‐ 

purpose, water‐resistant oil. 

6. Inspect the machine for water leaks and loose 

hardware. Repair/replace as necessary. 

7. Remove the ball float and clean the screen. 
8. Clean the in‐line solution filter (refer to the 

exploded view of the machine for the location). 

 

Machine Storage

1. Drain the machine completely of all liquid in 

the tanks. 

2. Turn the pump on and spray until all the liquid 

is pumped out and air is evident. 

3. Drain and dry the vacuum hose. 
4. Leave the lid off the recovery tank. 
5. Store the machine upright in a heated location. 

This manual is related to the following products: