beautypg.com

Minuteman E17_E20_H20 Walk-Behind Scrubber Disc Traction Drive User Manual

Page 33

background image

33

Troubleshooting

Problem Possible

Cause Remedy






Vacuum motor does not turn
on

Recovery tank full

Empty recovery tank

Excessive foaming in recovery tank.

Empty recovery tank.

Use less or change chemical.

Use defoaming agent.

Carbon Brushes worn

Replace carbon brushes

Vacuum switch disconnected

Connect wiring

Tripped vacuum motor circuit breaker

Reset breaker

Broken vacuum limit switch

Replace switch by squeegee lift lever

Squeegee in raised position Lower

squeegee



Brush does not unload

Foot pedal not in “home” position

Place pedal in notch

Tripped brush motor circuit breaker

Reset breaker

Broken brush motor switch

Replace switch

Damaged brush block or drive hub

Replace

Retaining ring on brush motor shaft not
in groove

Remove brush hub assembly and
slide ring into groove

Charger Warning Indicators

LED

Status

Description


Warning





RED LED lamp blink once

Output open circuit or short circuit or reverse polarity connection of
charger to battery. Battery voltage is too high (may be connected to
wrong voltage battery).

RED LED lamp blink twice

Abnormal cycle (may be weak or bad battery)
Charging time has safety timed out due to battery problem.