beautypg.com

Cfh-4000 in-line resin heater manual maintenance, Chapter – Magnum Venus Plastech CFH-4000 User Manual

Page 6

background image

6






CFH-4000 IN-LINE RESIN HEATER MANUAL
MAINTENANCE


(Refer to Parts Drawings)

1.

Periodically, the heater should be flushed out by pumping solvent through,
especially with gel coat or filled resin systems.


2.

Inspect electrical cord for wear or damage and repair or replace as necessary.

3.

Inspect hoses attached to the heater for wear of damage and replace
periodically.

4.

Check heater and hoses for leaks and replace periodically.


ALWAYS DISCONNECT POWER AND NEVER FLUSH WITH SOLVENT UNTIL
HEATER HAS COOLED TO ROOM TEMPERATURE. PRESSURE NOT TO
EXCEED 2500 PSI

















CHAPTER

3