Magnum Venus Plastech System One FRP 4101-00-01 User Manual
Page 6
FRP SystemOne
Gelcoat
7.
Remove and discard the 9201-1-5 (5/32” SS Ball).
8.
Remove and retain the 4101-3-1 (Piston Rod Spring).
9.
Unscrew the 4101-11-1 (Packing Nut) and pull the 4101-10-1
(Piston Rod) out of the 4101-14-1 (Outlet Body).
10. Insert a 1/4” diameter dowel into the bottom of the 4101-14-1
(Outlet Body), force the 4101-13-01 (Piston Rod Packings) and
4101-12-1(Upper Guide) out through the top of the Outlet Body and
discard.
11. Unscrew the 4101-2-1 (Cylinder) from the 4101-7-1 (Inlet Body).
Remove and discard the two 7301-9-014 (O-Rings). Inspect the
Cylinder for scratches, or other damage, and replace if necessary.
12. Remove and discard the 9201-1-14 (7/16” SS Ball). Inspect the
seat inside the 4101-7-1 (Inlet Body), for nicks, scratches, or other
damage, and lap, or replace if necessary.
13. Remove the 4101-8-1 (Tube Fitting). Remove and discard the
7301-9-013 (O-Ring).
3
WARNING
Use wrench flats provided in order to avoid damaging the Piston
Rod.
NOTE
Care must be taken to not damage the inside of the Outlet Body.
NOTE
Once disassembly is complete all parts should be flushed in
distilled water and inspected for damage and replaced if
necessary.
NOTE
Carefully pull the Piston Rod out of Cylinder to avoid damaging
the interior surface of Cylinder. Inspect the Piston Rod for
scratches or other damage. Replace if necessary.