Removing catalyst pump from system – Magnum Venus Plastech PATRIOT PAT-CP-0980-S User Manual
Page 17
PAT-CP-0980 Catalyst Pump Manual
Rev. 03/2013
Page | 17
Removing catalyst pump from system:
1.
Place clean 5-gallon pail under the catalyst pump to collect any potential spills.
2.
Close the main air supply ball valve to system.
3.
Open catalyst manifold ball valve to release fluid pressure.
4.
Use a 5/64” Allen wrench to release catalyst accumulator charge (see resin and
catalyst accumulator charging procedures in operations manual).
5.
Remove the catalyst jug from its bracket and set it in a position below the catalyst
pump. This may require pulling out the three ¼” poly tubing hoses from the top
of the catalyst jug depending on the unit configuration. Rock the jug back so the
outlet fitting will allow the catalyst to drain back into the jug from the feed hose.
Use a flat head screwdriver to remove the plastic hose clamp on the catalyst
pump inlet fitting. Remove the catalyst feed tube from the inlet fitting.
6.
Remove the catalyst swivel hose fitting from the outlet body of the catalyst pump.
7.
Push in the tube spilt bushing (4105-5-1) on the outlet body and pull off the ¼” poly
tubing.
8.
Remove the catalyst pump from the drive by first removing the ¼” hex bolt on the
bottom of the pump and then un-screw the knob (PAT-CP-3105) from the top of
the drive linkage.
Wipe the catalyst pump clean and inspect for damage and wear.