beautypg.com

Rd - 82 rack mount dimmer, Is intended for – Lightronics RD82 User Manual

Page 3

background image

Page

3

of

14

RD - 82 RACK MOUNT DIMMER

Version 1.2

OWNERS MANUAL

02/28/2005

www.lightronics.com

Lightronics Inc.

509 Central Drive, Virginia Beach, VA 23454

(757) 486-3588


UNIT DESCRIPTION AND FUNCTIONS

The RD-82 is a 19,200 Watt, 8 channel, rack mountable lighting dimmer. Each of the channels has a capacity of
2400 Watts. It is controlled via low voltage signals which may be LMX-128 (3 wire multiplex), or USITT DMX-512.
The unit is fan cooled. Channels may be independently assigned from the unit. The unit is over temperature and
over voltage protected and has a magnetic circuit breaker for each channel. There are several options for
channel output connection panels. Options include: Edison plug, Knockout panel with internal terminal strip,
External Terminal Strip, Patch panel, Stage pin panel, and Socapex Connector panel. The RD-82 also has
several "stand alone functions" which enable it to operate without a control console. These functions include a
storable scene which may be activated by an external switch closure, a programmable chaser, and 7 factory set
chase patterns.












POWER REQUIREMENTS

Each RD-82 requires SINGLE PHASE 240 VOLT AC or TWO PHASES OF A THREE PHASE 120/208 VOLT AC
service. The neutral conductor is shared by two hots so it is important that the two hots used are of different
phases. EACH PHASE must be capable of providing 80 AMPS. Line frequency is typically 60HZ. A 50HZ model
is available for export. Refer to the electrical rating markings on the dimmer to determine the operating
frequency. One or more RD-82 dimmers are to be installed into a standard 19" equipment rack with provisions for
connection to an appropriate electrical service in accordance with the National Electrical Code.

INSTALLATION

PLACEMENT

The RD-82 is designed to be mounted in a standard 19" equipment rack using the four mounting holes in the face
plate of the dimmer. If the dimming system will be used for touring shows, it is recommended that you provide
additional support for the rear of the unit. The dimmer is fan cooled and requires no space between units when
multiple dimmers are used. Air enters the dimmer through slots on the side and exits through holes in the bottom
of the face plate. Make certain these ventilation holes are not obstructed. Do not place the RD-82 where it will be
exposed to moisture or excessive heat.

The

RD-82

is intended for

INDOOR USE ONLY.


POWER CONNECTIONS

Make certain power is removed from the circuits before you begin installation of the dimmer. Consult your
local electrical codes to determine the proper wire type and wiring methods for your installation.

Power enters the RD-82 through a knockout sized hole at the rear of the unit. Remove the top cover and install
an appropriate cable clamp in the knockout hole. Pass the power cables through the hole. Behind the hole is a
terminal block with three lugs. The connections labeled "H1" and "H2" are the line or "hots". The center
connection labeled "N" is the neutral. There is an additional lug labeled "G" to the right of the terminal block. This
is for connecting the unit to earth ground. When connections are completed, reinstall the cover and tighten the
cable clamp.