Lightronics FXLD100ECMY26B User Manual
Page 2

Page
2
of
4
FXLD100ECMY26B LED FIXTURE
Version 0.1 OWNERS MANUAL 04/25/2012
www.lightronics.com
Lightronics
Inc.
509
Central
Drive
Virginia
Beach,
Va
234354
757
486
3588
DMX TERMINATION
A DMX chain should be terminated at the last
receiving device on the chain. This is done by
installing a commonly available 1/4 Watt, 120 Ohm
resistor across the DATA - and DATA + wires at the
last device. If you have only a few fixtures very close
together and a very short run to the controller then you
may be able to operate without the terminator.
OPERATION
A power ON/OFF switch is located at the rear of the
unit. A control panel on the back of the unit is used to
set the operating options. It consists of an LED display
and four buttons
(MODE, SAVE, UP, and DOWN)
Push MODE to access the operating options. Then use
UP
and
DOWN
to scroll the available choices. When
you reach the value you want to set - push
SAVE
.
There are 3 operation modes: DMX, F1, and F2.
DMX OPERATION
Use the
A - - - menu to set the starting address of the
unit. You can set the starting address of the unit with
the UP and DOWN buttons.
The fixture uses seven DMX channels with allocations
as follows:
CHANNEL 1: Iris Control
CHANNEL 2: Cyan Filter
CHANNEL 3:
Magenta Filter
CHANNEL 4:
Yellow Filter
CHANNEL 5:
CTO Filter
CHANNEL 6:
Master Dimmer Level
CHANNEL 7:
Strobe Rate
Additional detail on DMX channel operation is given
in the table "DMX Values and Functions".
AUTO MODES F1 and F2
The AUTO MODES switch continuously through a
sequence of colors.
Both F1 and F2 mode may be
turned on or off independently from the control panel.
A DMX signal must be present but is not used when
operating in F1 or F2 modes.
MAINTENANCE AND REPAIR
TROUBLESHOOTING
Check that you have power applied to the unit.
Check the DMX control cable.
Check the address settings of the unit and the
controller.
CLEANING
Do not use harsh chemicals or solvents when cleaning
the fixture. A mild detergent can be used sparingly if
needed. Ensure that the unit is completely dry before
re-u
se.
REPAIR
The only FXLD100ECMY26B user serviceable part is
a 5mm x 20mm externally accessible fuse.
DISCONNECT THE UNIT FROM POWER BEFORE
CHECKING OR REPLACING THE FUSE
Replace fuse ONLY with 3.15 Amp, 250VAC, fast
blow fuse.
Internal service on the unit by other than Lightronics
authorized agents will void the warranty.
If service is required, contact the dealer from whom
you purchased the item, or contact the Lightronics,
Service Department, 509 Central Drive, Virginia
Beach, VA 23454. Tel: 757 486 3588.
MODE
UP
DOWN
SAVE
CONTROL PANEL
CAUTION DO NOT OPEN UNIT
RISK OF ELECTRIC SHOCK
RISK OF FIRE