beautypg.com

Frequency scan mode – Lectrosonics UCR211 User Manual

Page 10

background image

UCR211

FREQUENCY SCAN MODE

Scan

Scan level
indications
­
showing
relative level of
RF activity
across the
25MHz bandwidth of
the receiver.

To use the integrated scanning function, press both UP/
DOWN buttons and the MENU button at the same time.
The display will switch to the SCAN WINDOW and start
scanning immediately. Data gathered during a scan is
stored until it is purposely erased or the power is turned
off. Previous data will remain and subsequent scans can
be made to search for additional signals or to accumu­
late higher peaks.

To stop scanning, press the MENU button once. The
scanning will stop immediately, and the display will
switch to the VIEW window. In this window, each vertical
band of the display represents eight frequencies (800
kHz). Pressing the UP or DOWN buttons will scroll the
cursor coarsely across the tuning range. The transmitter
switch settings matching the frequency indicated by the
cursor are shown in the upper right corner of the screen.

Spectrum data is collected only when the receiver is
scanning. Successive scanning with repeated passes
through the tuning range will accumulate the highest
peaks encountered to aid in finding clear frequencies. To
clear the scan memory without leaving scan mode, turn
the power switch off and back on quickly.

Pressing the MENU button once will shift the display to
the FINE VIEW window which will show an expanded
portion of the spectrum around the cursor.

In the FINE VIEW window, each vertical band represents
one frequency the receiver is capable of tuning. The
upper right corner shows the transmitter switch settings
for the. In this screen, a vertical center bar is the cursor.
Underneath the switch settings are two arrows to remind

B8

USE OLD
USE NEW

Freq

Window

View

Fine View

Press All 3 Buttons

To Exit Scan

Mode, Press All 3

Buttons From Any

Window.

B8

P

re

ss

A

ny

Bu

tton

Press Menu

Pr

es

s

M

e

n

u

B8

B8

Switch Settings ­
shows the
transmitter switch
settings - will
change rapidly while
the unit is scanning.

Cursor - shows relative
position of the scanner
within the 25Mhz band
of the receiver

RF Level

indicators

B8

Cursor

(center bar)

SCROLL

reminders

Remaining
unscanned part
of band.

SCAN AND VIEW WINDOW ELEMENTS

FINE VIEW WINDOW ELEMENTS

Transmitter

Switch

Settings

you that this is a partial picture of the spectrum and that
you can scroll left or right to view the entire spectrum of
the receiver by pressing the UP and DOWN buttons.

Pressing the UP button will make the display scroll left,
showing higher frequencies. Pressing the DOWN button
will make the display scroll right, showing lower frequen­
cies. The cursor remains in place while the display
scrolls left or right

In addition to assessing the congestion within the RF
tuning range of the receiver, the scanning mode is also
used to find a clear operating frequency. Scroll through
the screen and find a frequency where no RF signals are
present (or in the worst case, only very weak RF sig­
nals). With the cursor on this frequency, press the UP,
DOWN and MENU buttons at the same time to leave the
scan mode.

When leaving the scan mode, you are given the option of
using the frequency the unit was on before entering the
scan mode, or using the frequency just selected in the
scan mode. The display shows USE OLD and USE
NEW to prompt you to make a frequency selection. To
accept the new frequency just selected in the scan
mode, press the DOWN button for USE NEW. To return
to the frequency you were using before entering the scan
mode, press the UP button for USE OLD. (the MENU
button defaults to USE OLD).

Once you leave the scan mode, the Frequency Window
will be displayed. Set your transmitter switches to the
same settings as shown on the display and your system
will be ready for operation.

LECTROSONICS, INC