Replacing the power switch magnet housing assembly – Lectrosonics MM400c User Manual
Page 14

MM400C
LECTROSONICS, INC.
14
Although the Power Switch’s Magnet Housing Assembly
is designed to provide years of rugged use it may be-
come inadvertently damaged or lost. Use the following
procedure to install a new Magnet Housing Assembly.
1) Because of this, color the screwdriver blade or-
ange. If necessary, use a nonmetallic tool such as
an “orange stick” to remove the damaged Magnet
Housing Assembly and clean any debris from the
Magnet Housing Assembly slot. Apply a small
amount of petroleum jelly or white lithium grease to
the area before inserting the new magnet assembly.
Warning: If you use something metallic, as
illustrated in the example, use extreme caution
not to scratch the finish. Breaching the finish
may cause corrosion of the metal housing.
2) Notice that the Magnet Housing Assembly Slot has
a wide spot in the middle. Place the new Magnet
Housing Assembly in the slot so that one tab is in a
small groove in one side of the slot.
3) Use a nonmetallic implement to snap the other side
of the Magnet Housing Assembly into the slot.
4) Ensure a good battery is installed, then slide the
new Power ON/OFF Switch to ON to verify that it is
working properly.
Replacing the Power Switch Magnet Housing Assembly
Magnet Housing
Assembly
Place switch in center position so tabs will
clear the opening, gently pry switch out.