4. RECEIVING & UNPACKING YOUR TRANSMITTER

Your transmitter was carefully tested and inspected prior to shipment. Should the transmitter be
damaged in shipment, notify the freight carrier immediately. In the event the transmitter is not
configured as ordered or is inoperable, return it to the place of purchase for repair or replacement.
Please include a detailed description of the problem.

5. SAFETY CONSIDERATIONS

Warning: Use of this transmitter in a manner other than specified may impair the protection

of the device and subject the user to a hazard. Visually inspect the unit for signs of damage. If
the unit is damaged, do not attempt to operate.

Caution:

• This unit may be powered with AC (mains) from 95-240 Vac ±10% with the worldwide voltage

power supply option, or 12-30 Vac or 10-48 Vdc with the low voltage power supply option.
Verify that the proper power option is installed for the power to be used. This transmitter has
no AC (mains) switch. It will be in operation as soon as power is applied.

• The 95-240 Vac ±10% mains connector (P1 Pins 1-3) is colored Green to differentiate it from

other input and output connectors. The 12-30 Vac or 10-48 Vdc mains connector is colored
Black.

• To avoid dangers of electrocution and/or short circuit, do not attempt to open the case while

the unit is under power. However, signal wiring changes external to the case can be made
safely while the unit is under power.

• To prevent electrical or fire hazard, do not expose the transmitter to excessive moisture.

• Do not operate the transmitter in the presence of flammable gases or fumes. Such an

environment constitutes an explosion hazard.

Secure the transmitter to a 35 mm DIN rail.

Symbols used:

Caution (refer to accompanying documents)

Earth (ground) terminal.

Caution, risk of electric shock.

Both direct and alternating current.

Equipment protected throughout by double
insulation or reinforced insulation.

Operating environment:

Transmitter Class II (double insulated) equipment designed for use in Pollution degree 2.