1 relay strike time, 2 tone open numbers, 3 general programming – Controlled Products Systems Group 1812-087 User Manual
Page 25
2.3 GENERAL
PROGRAMMING
Proceed with the programming steps on the following pages if PC programming will not be used.
2.3.1 Relay Strike Time
These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4
second (enter 00 in step 4) up to 99 seconds by entering the desired time in seconds.
1.
Press * 0 3 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Press 1 * (beep) to set relay 1, or 2 * (beep) to set relay 2 strike time.
3.
Enter the two-digit strike time _ _ (00-99) then press * (beep).
4.
Repeat steps 2 and 3 to set other relay strike time.
5.
Press 0# TOGETHER to end this programming step (beeeeeep).
2.3.2 Tone Open Numbers
These steps will program the tone open number(s) for both relay 1 and relay 2. Each relay is
programmed independently. You will need to enter a four-digit number (see chart below) to set each
relay. If a function is not desired, enter # in place of a number. For example, if you want the relay to
have a momentary activation function only, and you want the relay to activate when the number 9 is
pressed, enter 9 # # # in step 3.
1.
Press * 0 5 and enter the four-digit MASTER CODE _ _ _ _ (beep).
2.
Press 1 * (beep) to set relay 1, or press 2 * (beep) to set relay 2.
3.
Enter the four-digit tone open number code _ _ _ _ then press * (beep).
4.
Repeat steps 2 and 3 to set the other relay tone open number(s).
5.
Press 0# TOGETHER to end this programming step (beeeeeep).
4 Digit Tone
Open
Number
Code
Function
1
st
Digit
Momentary activation. The relay will activate for its programmed strike time.
2
nd
Digit
Hold open. The relay will activate and remain activated until commanded to deactivate.
3
rd
Digit
Deactivate relay.
4
th
Digit
Hold open 1 hour. The relay will activate for 1 hour and then deactivate itself.
1812-065-M-3-07
Page