2.3 GENERAL

PROGRAMMING

Proceed with the programming steps on the following pages if PC programming will not be used.

2.3.1 Relay Strike Time

These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4
second (enter 00 in step 4) up to 99 seconds by entering the desired time in seconds.

1.

Press * 0 3 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Press 1 * (beep) to set relay 1, or 2 * (beep) to set relay 2 strike time.

3.

Enter the two-digit strike time _ _ (00-99) then press * (beep).

4.

Repeat steps 2 and 3 to set other relay strike time.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

2.3.2 Tone Open Numbers

These steps will program the tone open number(s) for both relay 1 and relay 2. Each relay is
programmed independently. You will need to enter a four-digit number (see chart below) to set each
relay. If a function is not desired, enter # in place of a number. For example, if you want the relay to
have a momentary activation function only, and you want the relay to activate when the number 9 is
pressed, enter 9 # # # in step 3.

1.

Press * 0 5 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Press 1 * (beep) to set relay 1, or press 2 * (beep) to set relay 2.

3.

Enter the four-digit tone open number code _ _ _ _ then press * (beep).

4.

Repeat steps 2 and 3 to set the other relay tone open number(s).

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

4 Digit Tone

Open

Number

Code

Function

1

st

Digit

Momentary activation. The relay will activate for its programmed strike time.

2

nd

Digit

Hold open. The relay will activate and remain activated until commanded to deactivate.

3

rd

Digit

Deactivate relay.

4

th

Digit

Hold open 1 hour. The relay will activate for 1 hour and then deactivate itself.

1812-065-M-3-07

Page

25