Controlled Products Systems Group 790919 User Manual
Page 10

Page 10
November, 2003
455 D Control Panel Installation Instructions
•
When gate operator (1) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase.
•
When gate operator (1) reaches the positive
stop and the desired motor run time has been
reached, an open command must be given to
shut the motor off. At this point gate operator
(2) will automatically start to open.
•
When gate operator (2) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase.
•
When gate operator (2) reaches the positive
stop and the desired motor run time has been
reached, an open command must be given to
shut the motor off. At this point gate operator
(2) will automatically start to close.
•
When gate operator (2) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase.
•
When gate operator (2) reaches the positive
stop and the desired motor run time has been
reached, an open command must be given to
shut the motor off. At this point gate operator
(1) will automatically start to close.
•
When gate operator (1) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase.
•
When gate operator (1) reaches the positive
stop and the desired motor run time has been
reached, an open command must be given to
shut the motor off.
The display stops flashing and the gate is ready for
normal operation.
L
EARNING
T
IMES
WITH
G
ATECODER
Learning with the Gatecoder can be done in two
different ways:
S
IMPLE
L
EARNING
Close the gates, enter “Basic Programming”, select the
TIME LEARNING function and press the + push-button
for 1 second: the display begins flashing and the leaves
begin the opening movement.
The movement stops automatically when the opening
positive stop is reached and the display stops flashing.
The procedure has ended and the gate is ready to
operate, using default slow down automatically set by
the control panel.
L
EARNING
OF
O
PERATING
T
IMES
WARNING: During the learning procedure, the
safety devices are disabled! Therefore, any traffic
must be avoided in the path of the gate leaf(s).
NOTE: Must start with gate(s) in the closed
position.
Opening/closing time is established by the learning
procedure which varies slightly according to whether
you are or are not using Gatecoders.
L
EARNING
OF
N
ORMAL
T
IMES
Normal learning (i.e. without Gatecoders) can be done in
two different ways:
S
IMPLE
L
EARNING
Close the gates, enter “B
ASIC
P
ROGRAMMING
”, select the
TIME LEARNING function and press the + push-button
for 1 second the display begins flashing and the leaves
begin the opening movement.
Wait for the leaves to reach the opening positive stop
and then supply an OPEN A command after the desired
motor run time has been reached (by push-button or
radio control) to stop the movement: the leaves stop
and the display stops flashing. One more command
given will close the gate.
The procedure has ended and the gate is ready to
operate.
C
OMPLETE
L
EARNING
N
OTES
:
•
If you do not wish to slow the gate operator(s)
down, wait for the gate to reach its positive
stop and supply two (2) consecutive open
commands (within 1 second).
•
If only one gate operator (1) is used, you must
go through the entire programming procedure,
as if you were programming for two gate
operators (2). When the operator has finished
opening, supply 5 open commands until the
gate operator begins to close, and then resume
normal operations.
Close the gates, enter “B
ASIC
P
ROGRAMMING
”, select the
TIME LEARNING function and press the + push-button
for more than 3 seconds: the display begins flashing
and leaf 1 begins opening. The following functions can
be commanded by the OPEN A (by push-button wired to
terminals 9 and 14, or radio control):