beautypg.com

CONTREX CX-1102 User Manual

Page 19

background image

Page 17

If the dancer moves from Full to approximately 3/4 of Full, the Wind roll is stopped, the Dancer will
be held in position, and the test Passes.

Fail test:

Check the following:

a. is web threaded into machine
b. drive armature and power wiring
c. is the drive enabled
d. gear reduction is correct

Press the "Page Up" key to restart this step (Wind Direction Test).

Pass test:

The CX-1102 will flash "Wind PASS" then "Pg Down" in the bottom center of the display.
Setup State {MP-59} will equal 9.

Proceed to End of Wind Direction Test.

If the wind axis is NOT under CX-1102 control, if App Select {CP-202} is a 3 (DT Unwind only):

1) Momentarily close the KeyLk input. The CX-1102 will montior the Wind feedback and the Dancer content
for movement away from the Full position to approximately 3/4 of Full.
2) Rotate the Wind roll in the forward direction.
3) When the dancer moves, the CX-1102 will change the WindEncPlrty {CP-269} value so WindRollRPM
{MP-13}
is a positive (no ‘-‘ sign) signal for forward rotation of the Wind roll, the dancer should be held in
position, and the test Passes.

Fail test:

Check the following:

a. is web threaded into machine
b. drive armature and power wiring
c. is the drive enabled

Press the "Page Up" key to restart this step (Wind Direction Test).

Pass test:

The CX-1102 will flash "Wind PASS" then "Pg Down" in the bottom center of the display.
Setup State {MP-59} will equal 9.

End of Wind Direction Test

Press the "Page Down" key to proceed to the next step.