Programming – Codelocks CL5020 Mortice Latch with Double Cylinder User Manual
Page 4

PROGRAMMING
ENTER NEW USER CODE
Program
01
Key Sequence
#Master Code
•
01
•
User Code ID (eg 05)
•
New Code (eg 4321)
••
Result
New code
4321 entered at User Code ID 05
(
•
when user enters code)
SUSPEND USER CODE
Program
02
Key Sequence
#Master Code
•
02
•
User Code ID (eg 05)
••
Result
User Code at ID
05 suspended
(
•
•
when user
05 enters code)
RESTORE USER CODE
Program
03
Key Sequence
#Master Code
•
03
•
User Code ID (eg 05)
••
Result
User Code at ID
05 restored
(
•
when user
05 enters code)
SUSPEND ALL USER CODES Program 04
Key Sequence
#Master Code
•
04
••
Result
All User Codes suspended
(
•
•
when all users enter code)
RESTORE ALL USER CODES Program 05
Key Sequence
#Master Code
•
05
••
Result
All User Codes restored
(
•
when all users enter code)
CHANGE UNLOCK TIME
Program
06
Key Sequence
#Master Code
•
06
•
enter open time
(range 2 – 9 secs)
••
Result
After code entry the lock will unlock for the set time
(Factory pre-set time is 4 seconds)
ONE TIME USER CODE
Program
07
Key Sequence
#Master Code
•
07
•
One time code ID
(eg 81)
•
One time Code (eg 4321)
••
Result
Code 4321 in position 81 will work once and then
be removed from memory
Note: ID Positions 81 to 90 are reserved for this
program function, allowing up to 10 One-Time
User Codes to be entered.
SET CODE FREE MODE
Program
08
Key Sequence
#Master Code
•
08
••
Result
Lock will be continuously unlocked
CANCEL CODE FREE MODE
Program
09
Key Sequence
#Master Code
•
09
••
Result
Lock will revert to normal operation
CHANGE MASTER CODE
*
Program
10
Key Sequence
#Master Code
•
10
•
enter length of Master Code
followed by new Master Code (eg 6, 123456)
•
confirm length of Master Code followed by new
Master Code (eg 6, 123456)
••
Result
Master Code now changed to #123456.
Note: If the
length of the Master Code is changed then all
previous User Codes will be deleted
CANCEL EMERGENCY OPEN MODE Program 11
Key Sequence
#Master Code
•
11
••
Result
The emergency unlocked condition via REM 2 will
be cancelled and the lock will revert to normal
operation
DELETE ALL USER CODES
Program
12
Key Sequence
#Master Code
•
12
•
12
••
(7 secs)
Result
All User Codes will be cleared from the memory
*
First change the factory Master Code #1234 – see program 10. If the Master or Sub Master
Code is entered 3 times consecutively without performing a programming function, a penalty
time of 10 seconds is activated.
Note: On the CL2000 and CL4000 locks the at the bottom of the keypad acts as the # button.
The Master Code and Sub-Master Code
MUST always start with #. Codes can only be the same length
as the Master Code. A
•
or
•
in the Key Sequence below indicates LED illumination.
IF ENTERED, A SUB-MASTER CODE CAN BE USED INSTEAD OF THE MASTER CODE FOR ALL PROGRAMS
EXCEPT PROGRAMS 10 AND 12.
•
Code accepted
•
Code rejected
•
•
Code(s) valid
but suspended
LOCKED/UNLOCKED STATUS Program 15
Key Sequence
1. #Master Code
•
15
•
1
••
=Locked, No LED
flashing (this is the default setting)
2. #Master Code
•
15
•
2
••
=Locked-Red
•
LED flashing
3. #Master Code
•
15
•
3
••
=Unlocked-Blue
•
LED flashing
Result
If activated LED’s will flash continuously every
5 seconds
Note: LED’s will not indicate unlocked mode by key
ADD/CHANGE SUB-MASTER CODE
Program
13
Key Sequence
#Master Code
•
13
•
Sub-Master Code (eg
2468)
••
Result
A Sub-Master Code #
2468 has been entered
DELETE SUB-MASTER CODE Program 14
Key Sequence
#Master Code
•
14
•
14
••
Result
Sub-Master Code has been deleted
6
7
- CL5010 Tubular Mortice Latch, Back to Back CL5010 Heavy Duty Electronic Tubular Mortice Latch CL5000 Panic Access Kit CL4020 Anti-Panic Mortice Lock, Double Cylinder CL4010 Electronic Tubular Mortice Latch CL4000 Electronic Glass Door Lock CL2255 Electronic Tubular Mortice Latch CL2210 Electronic Mortice Deadbolt CL2200 Electronic Surface Deadbolt