beautypg.com

Programming – Codelocks CL5020 Mortice Latch with Double Cylinder User Manual

Page 4

background image

PROGRAMMING

ENTER NEW USER CODE

Program

01

Key Sequence

#Master Code

01

User Code ID (eg 05)

New Code (eg 4321)

••

Result

New code

4321 entered at User Code ID 05

(

when user enters code)

SUSPEND USER CODE

Program

02

Key Sequence

#Master Code

02

User Code ID (eg 05)

••

Result

User Code at ID

05 suspended

(

when user

05 enters code)

RESTORE USER CODE

Program

03

Key Sequence

#Master Code

03

User Code ID (eg 05)

••

Result

User Code at ID

05 restored

(

when user

05 enters code)

SUSPEND ALL USER CODES Program 04

Key Sequence

#Master Code

04

••

Result

All User Codes suspended

(

when all users enter code)

RESTORE ALL USER CODES Program 05

Key Sequence

#Master Code

05

••

Result

All User Codes restored

(

when all users enter code)

CHANGE UNLOCK TIME

Program

06

Key Sequence

#Master Code

06

enter open time

(range 2 – 9 secs)

••

Result

After code entry the lock will unlock for the set time

(Factory pre-set time is 4 seconds)

ONE TIME USER CODE

Program

07

Key Sequence

#Master Code

07

One time code ID

(eg 81)

One time Code (eg 4321)

••

Result

Code 4321 in position 81 will work once and then

be removed from memory
Note: ID Positions 81 to 90 are reserved for this

program function, allowing up to 10 One-Time

User Codes to be entered.

SET CODE FREE MODE

Program

08

Key Sequence

#Master Code

08

••

Result

Lock will be continuously unlocked

CANCEL CODE FREE MODE

Program

09

Key Sequence

#Master Code

09

••

Result

Lock will revert to normal operation

CHANGE MASTER CODE

*

Program

10

Key Sequence

#Master Code

10

enter length of Master Code

followed by new Master Code (eg 6, 123456)

confirm length of Master Code followed by new

Master Code (eg 6, 123456)

••

Result

Master Code now changed to #123456.

Note: If the

length of the Master Code is changed then all

previous User Codes will be deleted

CANCEL EMERGENCY OPEN MODE Program 11

Key Sequence

#Master Code

11

••

Result

The emergency unlocked condition via REM 2 will

be cancelled and the lock will revert to normal

operation

DELETE ALL USER CODES

Program

12

Key Sequence

#Master Code

12

12

••

(7 secs)

Result

All User Codes will be cleared from the memory

*

First change the factory Master Code #1234 – see program 10. If the Master or Sub Master

Code is entered 3 times consecutively without performing a programming function, a penalty

time of 10 seconds is activated.

Note: On the CL2000 and CL4000 locks the at the bottom of the keypad acts as the # button.

The Master Code and Sub-Master Code

MUST always start with #. Codes can only be the same length

as the Master Code. A

or

in the Key Sequence below indicates LED illumination.

IF ENTERED, A SUB-MASTER CODE CAN BE USED INSTEAD OF THE MASTER CODE FOR ALL PROGRAMS

EXCEPT PROGRAMS 10 AND 12.

Code accepted

Code rejected

Code(s) valid
but suspended

LOCKED/UNLOCKED STATUS Program 15

Key Sequence

1. #Master Code

15

1

••

=Locked, No LED

flashing (this is the default setting)

2. #Master Code

15

2

••

=Locked-Red

LED flashing

3. #Master Code

15

3

••

=Unlocked-Blue

LED flashing

Result

If activated LED’s will flash continuously every

5 seconds
Note: LED’s will not indicate unlocked mode by key

ADD/CHANGE SUB-MASTER CODE

Program

13

Key Sequence

#Master Code

13

Sub-Master Code (eg

2468)

••

Result

A Sub-Master Code #

2468 has been entered

DELETE SUB-MASTER CODE Program 14

Key Sequence

#Master Code

14

14

••

Result

Sub-Master Code has been deleted

6

7