Installation, Communication protocol setup, Input sensor active type – CNB SDN-23Z27FW User Manual
Page 9
XPEED Outdoor Series WWW.CNBTEC.COM
2. Installation
■ Communication Protocol Setup
• Select the appropriate Protocol With DIP switch combination.
Switch state
Protocol/Baud rate
P0 (Pin 1)
P1(Pin 2)
P2(Pin 3)
OFF
OFF
OFF
PELCO-D, 2400bps
ON
OFF
OFF
PELCO-D, 9600bps
OFF
ON
OFF
PELCO-P, 4800bps
ON
ON
OFF
PELCO-P, 9600bps
OFF
OFF
ON
SAMSUNG, 4800bps
ON
OFF
ON
PANASONIC, 9600bps
Others
Reserved
• If you want to control using DVR or P/T controller, their protocol must be identical to camera.
Otherwise, you can not control the camera.
• It you changed camera protocol by changing DIP S/W, the change will be effective after you
reboot the camera.
• Factory default of protocol is “Pelco-D, 2400bps”.
■ Input Sensor Active Type
• When a sensor input is used, its functional type should be set.
There are two types; Normal Open type and Normal Close type.
-Normal Open : Voltage is let out when the sensor is activated
-Normal Close : Voltage is let out when the sensor is not activated
Pin
Switch position
Sensor type
ST1 (Pin 4)
ON
Sensor 1 Normal Close
OFF
Sensor 1 Normal Open
ST2 (Pin 5)
ON
Sensor 2 Normal Close
OFF
Sensor 2 Normal Open
ST3 (Pin 6)
ON
Sensor 3 Normal Close
OFF
Sensor 3 Normal Open
ST4 (Pin 7)
ON
Sensor 4 Normal Close
OFF
Sensor 4 Normal Open
• If a wrong type of sensor is selected, it activates in the opposite way to the sensor input.
9