XPEED Outdoor Series WWW.CNBTEC.COM

2. Installation

■ Communication Protocol Setup

• Select the appropriate Protocol With DIP switch combination.

Switch state

Protocol/Baud rate

P0 (Pin 1)

P1(Pin 2)

P2(Pin 3)

OFF

OFF

OFF

PELCO-D, 2400bps

ON

OFF

OFF

PELCO-D, 9600bps

OFF

ON

OFF

PELCO-P, 4800bps

ON

ON

OFF

PELCO-P, 9600bps

OFF

OFF

ON

SAMSUNG, 4800bps

ON

OFF

ON

PANASONIC, 9600bps

Others

Reserved

• If you want to control using DVR or P/T controller, their protocol must be identical to camera.

Otherwise, you can not control the camera.

• It you changed camera protocol by changing DIP S/W, the change will be effective after you

reboot the camera.

• Factory default of protocol is “Pelco-D, 2400bps”.

■ Input Sensor Active Type

• When a sensor input is used, its functional type should be set.

There are two types; Normal Open type and Normal Close type.

-Normal Open : Voltage is let out when the sensor is activated
-Normal Close : Voltage is let out when the sensor is not activated

Pin

Switch position

Sensor type

ST1 (Pin 4)

ON

Sensor 1 Normal Close

OFF

Sensor 1 Normal Open

ST2 (Pin 5)

ON

Sensor 2 Normal Close

OFF

Sensor 2 Normal Open

ST3 (Pin 6)

ON

Sensor 3 Normal Close

OFF

Sensor 3 Normal Open

ST4 (Pin 7)

ON

Sensor 4 Normal Close

OFF

Sensor 4 Normal Open

• If a wrong type of sensor is selected, it activates in the opposite way to the sensor input.





9