Rev.1.0 (Dec. 2013)

13

Relay Output

Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.

Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable

of switching

30V AC/DC, 2A

. For the application which needs power switching beyond this limit, use

additional relay switch as shown in the right of Figure 2-1.

* Left : switching requirement below 30V, 2A

* Right : switching requirement higher than 30V, 2A. Apply this connection when either volt

age or current exceed the limit.

Figure 2-1. RELAY Output connection

Sensor Input

Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor,

heat/smoke sensor, magnetic sensor, etc. Connect the two wires of the sensors to “SNS In”. The sensor

type(NC/NO) can be set in admin page. Multiple sensor devices can be connected in parallel.

Figure 2-2. SENSOR input and connection of the sensor

Factory Default Switch

Open the dome cover and press the switch for a few seconds while power is applied.

Photo Coupler

NO/NC Type

Open Collector Type

Sensor1+

Sensor

Device

Sensor1-

Sensor

Device

Sensor

Power

Supply

Sensor

Power

Supply

GND

+12V

Alarm

Out

Device

Power

Supply

( ~30V)

( ~ 2A)

(DC/AC)

Alarm

Out

Device

Power

Supply

(30V~ )

( 2A~ )

(DC/AC)

Optional

Relay

Switch

Power

Supply

( ~30V)

( ~ 2A)

(DC/AC)

Relay

Relay