Alarm Input

Wires from various sensor type (IR, heat, and magnetic) can be connected to Alarm in(+)/(-) terminal as
shown in figure 2.5. (NC or NO of sensor input can be selected at Menu screen.)

Alarm Sensor device requires a separate power source.

Figure 2-5. Connecting to Alarm Input

z

Alarm Output

This terminal can only be connected up to AC 30V/400mA or DC 30V/400mA. An additional relay device
has to be used to control higher voltage or current.

Internal Circuitry External Circuitry

Figure 2-6. Connecting to Alarm Output