Etup and, Onfiguration – Cleveland Motion Controls DIN Rail Amplifier MWI-13261 Ultra Series Isolated REV BA User Manual
Page 10

DIN
R
AIL
A
MPLIFIER
,
MWI-13261
U
LTRA
S
ERIES
MAN-13261
U
LTRA
R
EV
BA
2 S
ETUP AND
C
ONFIGURATION
2.1 L
OAD
C
ELL
(T
RANSDUCER
)
T
ERMINALS
Supply
Terminal
Function
Description
Notes
J1-1
EXC RET
Supply return for bridge
excitation
Zero voltage terminal for
LCH and RCH transducers
COMMON
J1-4
+V EXC
Bridge excitation source for
LCH and RCH transducers
5.0 Volt or 10.0 Volt supply
terminal,
max. load 100 mA
J1-2
-IN LCH
Load cell signal from LCH
transducer
Low going output from LCH
transducer
10K ohm line-to-line
J1-3
+IN LCH
Load cell signal from LCH
transducer
High going output from LCH
transducer
J1-5
-IN RCH
Load cell signal from RCH
transducer
LOW going output from RCH
transducer
10K ohm line-to-line
J1-6
+IN RCH
Load cell signal from RCH
transducer
High going output from RCH
transducer
J1-7
OPEN (N.C.)
NO CONNECTION
Make no connection
J1-8
SHLD DRN
Cable shield
drain terminal
Cable Shield for LCH and RCH
transducer cables
Connect only at amplifier
Transducers (load cells) use strain gages which have limited insulation levels to ground (earth).
This requires that the COM terminals be connected to ground (earth) to prevent damage to the
transducers (load cells).
2.2 P
OWER
S
UPPLY
T
ERMINALS
Supply
Terminal
Function
Description
Notes
J2-1
24V RET
Power Supply
Power supply return
Must not exceed 50 volts
from P.E.
J2-2
+24 VDC
Power Supply
Positive supply source
+20 to +28 VDC
@ 180 mA max
A fuse with a rating of 0.38A must be used in the 24 VDC supply lead to limit potential damage
to the amplifier in the event of circuit malfunction.
2.3 O
UTPUT
T
ERMINALS
Output
Terminal
Function
Description
Notes
J2-3
COMMON
Output signal return
Common for +/- 10V and +/-
2V output
J2-4
+/- 10V OUT
Voltage Output signal
Undamped bi-polar
tension signal
max. load 2 mA
J2-5
mA MTR RET
mA meter signal
Used for current format meter
return
Current through 1 mA meter
returns here
J2-6
METER OUT
Output signal
Damped bi-polar tension signal
Switchable 2.0 V F.S.
or 1 mA F.S.
J2-7
4-20mA OUT
Current loop Output signal
Undamped tension signal,
current loop source
Internal Loop supply
J2-8
4-20mA RET
Output current signal
Current return for
4-20 mA loop
At -15 VDC with respect to
common
P
AGE
10
OF
30