beautypg.com

Start-up continued, Start-up and operation, Warning – King Technology Aqua Smarte Plus Mineral Dispensing System Model 7700 User Manual

Page 6: If using another means of chlorine support

background image

Start-up and Operation

Set control dial by matching up the parameters of your pool on the chart below. THIS IS A STARTING POINT ONLY and may
need to be adjusted to fit your individual pool needs. See #8 below for directions. IMPORTANT: Pump run times less than
8 hours could result in under chlorination due to inadequate flow through the System.

7.

For the first week test the pool water daily
for free chlorine with Aqua Smarte Brand
Test Strips to ensure correct dial setting.
Continue to test weekly throughout the
season.

8.

After each testing, adjust the dial
up by 1/2 increment if the free
chlorine reading has dropped
below 0.5 ppm or adjust down by
1/2 increment if the reading has
risen above 1.0 ppm. Continue
this process each day until the free
chlorine reading stabilizes to at
least 0.5 ppm.

Remember to adjust dial by 1/2 increments only in
order to prevent over chlorination which may bleach pool
surfaces.

Shock pool every two weeks or as needed
to maintain water quality. Follow label
directions on the shock treatment used.

6.

Set dial to Setting 5. Maintain a
minimum chlorine reading of 0.5
ppm with a chlorine delivery device
or hand feeding.

7.

Shock pool every two weeks or as needed
to maintain water quality. Follow label
directions on the shock treatment used.

If using another means of chlorine support

, follow

steps 1-5 on page 5 then continue below.

Find your starting dial setting by matching up the

parameters of your pool on the above chart. An above

ground pool with approximately 12,000 gallons with a 1

horse pump running 12 hours a day would require a starting

setting of 4.5. See example at right.

* – Bypass installation recommended.

RECOMMENDED FLOW RATE: 20-60 gpm

NR – This pump size is not recommended for this size pool.

Most common pool sizes

9.


WARNING

Do not add shock in or near the skimmer or
into the Aqua Smarte Plus

D

ocking Station

as it could damage equipment, risk potential


WARNING

Do not add shock in or near the skimmer
or into the Aqua Smarte Plus

D

ocking

Station as it could damage equipment, risk
potential explosion or discolor your pool
surface.

Above Ground

POOL SIZE

Gallons Diameter

8 HOUR PUMP RUN TIME

12 HOUR PUMP RUN TIME

24 HOUR PUMP RUN TIME

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

7,000 (18’)

5.0

4.5

4.0

3.5

4.5

4.0

3.0

5.0*

3.5

3.0

2.5

4.0*

9,000 (21’)

5.5

5.0

4.5

4.0

5.0

4.5

4.0

5.5*

4.0

3.5

3.0

4.5*

12,000 (24’)

6.0

5.5

5.0

4.5

5.5

5.0

4.5

4.0

4.5

4.0

3.5

5.0*

15,000

NR

6.0

5.5

5.0

6.0

5.5

5.0

4.5

5.0

4.5

4.0

3.5

20,000

NR

NR

6.0

5.5

NR

6.0

5.5

5.0

5.5

5.0

4.5

4.0

Above Ground

POOL SIZE

Gallons Diameter

8 HOUR PUMP RUN TIME

12 HOUR PUMP RUN TIME

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

7,000 (18’)

5.0

4.5

4.0

3.5

4.5

4.0

3.0

5.0*

9,000 (21’)

5.5

5.0

4.5

4.0

5.0

4.5

4.0

5.5*

12,000 (24’)

6.0

5.5

5.0

4.5

5.5

5.0

4.5

4.0

15,000

NR

6.0

5.5

5.0

6.0

5.5

5.0

4.5

20,000

NR

NR

6.0

5.5

NR

6.0

5.5

5.0