Hach-Lange HQD - Conductivity probe CDC User Manual
User instructions, Safety information, Overview
1
DOC272.53.80022
User instructions
Conductivity probe: Model CDC40101, CDC40103, CDC40105, CDC40110,
CDC40115, CDC40130
Safety Information
Precautionary Labels
Read all labels and tags attached to the instrument. Personal injury or damage to the
instrument could occur if not observed.
Overview
shows the graphite, 4-pole CDC401 series conductivity probe. The
CDC40105, CDC40110, CDC40115 or CDC40130 rugged conductivity probe is available with
a 5, 10, 15 or 30 meter cable. The CDC40101 or CDC40103 standard conductivity probe is
available with a 1 or 3 meter cable. The conductivity probe provides measurement of electrical
conductivity, salinity, resistivity or total dissolved solids (TDS) in wastewater, drinking water
and general applications.
Specifications
Specifications are subject to change without notice.
Electrical equipment marked with this symbol may not be disposed of in European public disposal systems after 12 August of 2005. In conformity
with European local and national regulations (EU Directive 2002/96/EC), European electrical equipment users must now return old or end-of life
equipment to the Producer for disposal at no charge to the user.
Note: For return for recycling, please contact the equipment producer or supplier for instructions on how to return end-of-life equipment,
producer-supplied electrical accessories, and all auxiliary items for proper disposal.
Specification
Details
Conductivity range
0.01 µS/cm to 200.0 mS/cm
Cell constant
0.40 cm
-1
± 10%
Conductivity resolution
0.0 to 19.99 µS/cm: 0.01 µS/cm
20.0 to 199.9 µS/cm: 0.1 µS/cm
200 to 1999 µS/cm: 1 µS/cm
2.00 to 19.99 mS/cm: 0.01 mS/cm
20.0 to 200.0 mS/cm: 0.1 mS/cm
Conductivity accuracy
± 0.5% of reading
TDS range
0 to 50,000 mg/L as NaCl
TDS accuracy
± 0.5% of reading
TDS resolution
0.0 to 19.99 mg/L: 0.01 mg/L
200 to 1999 mg/L: 1 mg/L
2.00 to 19.99 g/L: 0.01 g/L
20.0 to 50.0 g/L: 0.1 g/L
Salinity range
0 to 42 (ppt) (‰)
Salinity accuracy
± 1 parts per thousand (ppt) (‰)
Salinity resolution
0.01 parts per thousand (ppt) (‰)
Temperature range
-10.0 to 110.0 °C (14 to 230 °F)
Storage temperature
0 to 40 °C (32 to 104 °F)
Temperature accuracy
± 0.3 °C (± 1.09 °F)
Minimum sample depth
45 mm (1.77 in.)
Dimensions
Diameter: 14 mm (0.55 in.), Length: 103 mm (4.06 in.), Total length: 220 mm (8.66 in.),
Cable length (standard): 1 or 3 meter (3.28 or 9.84 ft); Cable length (rugged): 5, 10, 15
or 30 meter (16.4, 32.8, 49.2, or 98.4 ft)
Cable connection
Digital output and connector compatible with HQd meters
Warranty
Sensor is covered by a 1 year warranty