Definition of the cell constant value, Definition of the temperature compensation mode – Hach-Lange POLYMETRON 83xx User Manual User Manual
Page 19

2 E
LECTRODES
C
ONDUCTIVITY
P
ROBE
- I
NSTRUCTION
M
ANUAL
 
 
 
 
621=183=000 Issue B
09/2010
Page 15
• « Average conductivity » zone:
No particular precautions in this zone: 
choose f = 1 kHz. 
• « High conductivity » zone:
When the measurement frequency is low, 
the surface of the electrodes will very 
quickly saturate (formation of an insulating 
layer reducing the flow of current, a 
phenomenon known as "polarisation"). 
Choose f > 1 kHz 
REMARK
9125 : select the "automatic frequency" 
mode, in order to automatically set the best 
frequency according to the measurement 
range. 
Definition of the cell constant value:
Enter real cell constant value of the probe (this 
value is indicated in the certificate, it is 
determined with a precision < 
2
% in
compliance with ASTM D 1125 and ISO7888 
standards). 
 
Definition of the temperature 
compensation mode: 
Programm the mode of temperature 
compensation of the transmitter according to 
the characteristics of the process (see & 1, 
influence of the temperature). 
 
- AMTAX sc (118 pages)
 - PHOSPHAX sc (106 pages)
 - CL17 Instruction sheet (8 pages)
 - CL17 USER MANUAL (60 pages)
 - CLF10 sc (382 pages)
 - 9184 sc (50 pages)
 - POLYMETRON 9611 sc Installation (398 pages)
 - POLYMETRON 9610 sc Maintenance and Troubleshooting (286 pages)
 - POLYMETRON 9611 sc USER INSTRUCTIONS: SEQUENCER LINE INSTALLATION (2 pages)
 - POLYMETRON 9611 sc USER INSTRUCTIONS: SS SAMPLE CONDITIONING (4 pages)
 - HACH 5500 sc Installation (408 pages)
 - HACH 5500 sc Maintenance and Troubleshooting (286 pages)
 - HACH 5500 sc PO43-HR Operations (390 pages)
 - HACH 5500 sc PO43-LR Operations (392 pages)
 - HACH 5500 sc SiO2 Installation (418 pages)
 - HACH 5500 sc SiO2 Operations (394 pages)
 - POLYMETRON 9610 sc SiO2 Installation (410 pages)
 - POLYMETRON 9240 Basic User Manual (162 pages)
 - POLYMETRON 9240 Operator Manual (144 pages)
 - PHOSPHAX sigma Basic User Manual (305 pages)
 - AMTAX inter2 Basic User Manual (377 pages)
 - GANIMEDE P (60 pages)
 - BODTrak II Basic User Manual (172 pages)
 - BODTRACK II User Manual (28 pages)
 - BODTRAK II: Respirometric Biochemical Oxygen Demand (BOD) (46 pages)
 - SPECTRO COLOR d-8 (29 pages)
 - REFO 60_REFO 60D (36 pages)
 - REFO 3_REFO 3D (19 pages)
 - LICO 620 Basic User Manual (329 pages)
 - LICO 620 User Manual (114 pages)
 - SD900 (2 pages)
 - LZX971 (8 pages)
 - SC Sensor Plug and SC Sensor Coupling (8 pages)
 - HQ Series Portable Meters (4 pages)
 - LDO Sensor Replacement Kit for use with Hach HQ10 and HQ20 (43 pages)
 - LDO Sensor Replacement Kit (8 pages)
 - SIP 10 (273 pages)
 - SC 100 (58 pages)
 - SI792 E_T Quick start guide (2 pages)
 - SI792(x) E HACH GLI 3700 series SI792(x) T 7MA2200 and 8398 series User Manual (116 pages)
 - SI792 D Quick start guide (2 pages)
 - SI792 D, SI792x D, SI792x D-FF, SI792x D-PA User Manual (98 pages)
 - SI794 C and SI794 D Short instructions (2 pages)
 - SI794 D tr User Manual (108 pages)
 - SI792 C Quick start guide (2 pages)
 
