1. The first option setting display that appears in the Program Mode is Treated Water Capacity. Using the

Set Up or Down Buttons, set the amount of treated water that can flow through the unit before a
regeneration is required. For Example:

2. Push the Extra Cycle Button. The second option setting display that appears is Regeneration Time. Using

the Set Up or Down Buttons, set the desired time of day when a regeneration can occur, is required. For
Example:

3. Push the Extra Cycle Button. The third option setting display that appears is Regeneration Day Override.

Using the Set Up or Down Buttons, set the maximum number of days before a regeneration cycle must
occur. For Example:

650 Gallons Capacity

2:00 A.M. Regeneration Time

Regenerate Every

7 Days Minimum

Service

Program

Flow

P.M.

6 5 0

Service

Program

Flow

P.M.

2:00

Service

Program

Flow

P.M.

A - - 7

Program Mode Indicator:

Program Mode Entered - Dot On

Extra Cycle Button

Set Up
Button

Set Down
Button

This is an option only. Please do not adjust before consulting an authorized dealer.