Operating instructions – Hydrotech 5600 SE Valve Downflow Automatic Water Softeners Operation Manual User Manual

Page 5

background image

4

Operating Instructions

The valve has been pre-programmed with factory settings as follows:

Regeneration Cycle Step Programming
1. Backwash ..................................10 minutes
2. Brine Rinse ..................................60 minutes
3. Rapid Rinse ................................10 minutes
4. Brine Refill ..................................3 minutes - 5600SEM-835-50 / CAB5600SEM-835-50

5 minutes - 5600SEM-844-75
7 minutes - 5600SEM-948-100
7 minutes - 5600SEM-1035-100 / CAB5600SEM-1035-100
8 minutes - 5600SEM-1047-125
10 minutes - 5600SEM-1054-150
13 minutes - 5600SEM-1252-200
20 minutes - 5600SEM-1450-250

Set Time of Day

Refer to Figure 4. Push either the UP or DOWN keys to adjust the time of day by one digit. Press and hold either UP or
DOWN key to adjust time of day by several digits.

Enter Control Programming Mode

1.

Push and hold for 5 seconds both the UP and DOWN keys to enter Programming Mode.

2.

The first option display to appear is the Treated Water Capacity. To calculate the Treated Water Capacity, use the
following formula:

Unit Capacity in Grains (see Specifications - Page 1)

÷

water hardness (gpg) =

gallons

gallons - (75 gallons x no. people in the house) =

Treated Water Capacity

Example: 24,000 grain capacity unit, 20 gpg water hardness, 4 people in household

24,000 grains

÷

20 gpg = 1,200 gallons

1,200 gallons - (75 gallons x 4) = 900 gallons

Set Treated Water Capacity to 900 gallons

3.

Push the Extra Cycle button to advance to the second option setting. The setting that appears is the Regeneration
Time. Use the UP or DOWN keys to set the desired time of day for regeneration. The default setting is 2:00 A.M.

4.

Push the Extra Cycle button. The third option setting display that appears is Regeneration Day Override. Use the
UP or DOWN keys to set the maximum days before a regeneration cycle must occur. The default is
{A--Off). This is an option only, please do not adjust before consulting an authorized dealer.

5.

The Control Programming is now complete. Push the Extra Cycle button. This will exit the control from the
Programming Mode and resume to normal operation.

Figure 4

Set Down Button

Set Up Button

P.M. Indicator

Flow Indicator:

Flashing Dot With Water Flow

Service Indicator:

Valve in Service - Dot On
Extra Cycle Tonight - Flashing Dot