beautypg.com

Troubleshooting guide – Hydrotech PURA QCUF Quick Change Ultrafiltration Drinking Water System User Manual

Page 21

background image

19

If a problem cannot be corrected through the use of this troubleshooting guide please have the following information
ready prior to calling the 1-800 number on the back of this manual:

• Serial #
• Model #

Problem

Possible Cause

remedy

1. Insufficient

quantity of

product water

available to

service.

a. Plugged prefilter.

a. Replace filter element.

b. Plugged polishing filter.

b. Replace polishing filter.

c. UF membrane fouled with sediment.

c. Replace UF membrane and prefilter

elements.

2. Poor product

water quality.

a. All of (1) above.

a. All of (1) above.

b. UF membrane worn out.

b. Replace UF membrane.

3. Bad tasting product

water.

a. Decrease in product quality; see (2)

above.

a. Same as (2) above.

b. Polishing filter exhausted.

b. Replace polishing filter

4. External leakage.

a. Tubing not fully seated in fitting

a. Check all fittings for tightness.

b. Tubing abraded in seal area.

b. Recut tubing and redo connection.

5. Bad smell from

product water.

a. Polishing filter exhausted.

a. Replace polishing filter.

b. Prefilter element.

b. Replace filter element.

c. Unit needs disinfection.

c. Sanitize unit.

6. Black specks in

product water.

a. Carbon fines.

a. Flush polishing filter.

7. Low faucet

pressure.

a. Polishing filter plugged.

a. Replace polishing filter.

Troubleshooting Guide