Activating the system, Do not use the first storage tank of water – Hydrotech 1240 Series ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS User Manual
Page 15
9
ACTIVATING ThE SYSTEM
CAUTION: Make sure all water supply lines, drain lines, and fittings are secure and free from leakage.
1. open source water supply valve. Close product water faucet.
Check for leakage.
2. Turn tank valve one-quarter turn counter- clockwise to open
valve (handle should be in line with tubing as it enters connec-
tion).
3. Confirm system is producing water. Module will be sending rinse
water to drain.
Optional Smartap
®
Water Quality Monitor
Perform Steps 4 - 7
4. remove manifold cover if attached by gently lifting cover up
and away from manifold.
CAUTION: Wiring within module cover connects monitor compo-
nents. If wires, circuit board, or connections are damaged and/
or wetted, monitor will not function.
5.
CAUTION: Verify battery connector alignment before making
connection (Figure 9).
Connect battery on manifold by pressing clip onto
battery terminals.
6. replace manifold cover by gently pushing cover onto manifold
until it snaps into place.
7. Test battery connection by activating monitor. Press push
button. if either indicator light illuminates, connection is good.
NOTE: Release button after light illuminates. Test is to confirm
battery connection, not water quality.
8. Open product water faucet and let water flow until all air has
been expelled from system.
9. Close product water faucet. in 30 minutes, check connections
for leaks and correct if necessary.
Icemaker/Extra point of use: Check connections on these supply
lines for leaks.
10. Allow storage tank to fill overnight.
11.
WARNING: DO NOT USE THE FIRST FULL STORAGE TANK OF WATER
Discard (to drain) first full tank of water by opening product
water (and extra point-of-use) faucet until water flow stops, then
close faucet. This will flush sanitizing solution from system.
Icemaker: Let tray/bin fill with ice cubes. Discard all ice cubes.
This flushes sanitizing solution from lines to icemaker.
12. System is ready to use. Should there be any aftertaste or odor to
water or ice cubes, repeat Steps 10 and 11.
DO NOT USE ThE FIRST STORAGE TANk OF WATER
Allow storage tank to fill overnight. Dispense this water to drain.
This process removes factory-installed sanitizing solution from the entire system and sends it to drain.
This process also sanitizes fittings and tubing used during installation.
MAINTENANCE PROCEDURE PREPARATION
RECOMMENDATIONS
HAVE ALL EQUIPMENT AND REPLACEMENT COMPONENTS ON HAND AND READy BEFORE BEGINNING PROCEDURE.
A CLEAN WORk AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLy CLEAN AND/OR SANITIZE THE SySTEM.
(i.e., CLEAN HANDS, TOOLS, WORk SURFACE, AND CONTAINERS)
EQUIPMENT NEEDED
Safety glasses
Rubber gloves, sanitary
Wash Cloth, Clean and Lint-free
Liquid dish soap
Household bleach - Unscented Only
(5 1/4% sodium hypochlorite)
Plastic storage bag
Manual Air Pump
Plastic bucket
Plastic bowl
“O” ring Lube FDA Approved