Model 7000 – Hydrotech 7000 Service Manual User Manual
Page 11
![background image](/manuals/332362/11/background.png)
Model 7000
11
Programming a Meter Immediate Regenerated System
1.
Feed water hardness (Display Code H).
The feed water hardness setting displays only if the system is set to operate as a Meter Immediate or Meter
Delayed system type.
— Press the Set Up and Set Down buttons to set the amount of feed water hardness (grains/gallon or
degrees). The system automatically calculates treated water capacity based on the feed water hardness
and the system capacity preset in the Master Programming mode.
Example:
Range: 4 – 199 US and Metric
— To program 9 grains / gallon (US) or 9 degrees (Metric) [H – 9]
— Press the Set Up and Set Down buttons to adjust this value.
— Press the Extra Cycle button once to Exit Setup Programming Mode or press and hold the Up and Down
buttons simultaneously for five (5) seconds to enter the Extended Setup Programming Mode.
2.
EXTENDED Programming Mode
Regeneration Cycle Step Programming (Display Code 1 – 6)
This Program Step is used to program the Regeneration Cycle step times. The Regeneration Cycle Step being
programmed is displayed in the first digit of the display. Each display is used to set the duration time in minutes
of that specific step in the Regeneration cycle.
Example:
Figure 9: Feed Water Hardness
Cycle Step
dF
dFFF
FLtr
1
10 = Backwash
12 = Refill
10 = Backwash
2
60 = Brine Draw
60 = Brine Making
10 = Rapid Rinse
3
5 = 2nd Backwash
10 = Backwash
4
10 = Rapid Rinse
60 = Brine Draw
5
12 = Refill
5 = 2nd Backwash
6
10 = Rapid Rinse
Figure 10: Extended Programming Mode