7000 Master Programming Mode

Page 4

3.

Regeneration Type (Display Code 7)

Use this program step, identified by the number 7 in the first digit of the display, to set the Regeneration Type.
There are 4 possible settings:

Default = Meter Delayed Regeneration [ 7 - - 3 ]

Available Regeneration Types and their Dependencies

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button to proceed to the next step.

Time Clock Delayed

Setting: [ 7 - - 1 ]

The control regenerates on the days set in program step #7, at the Regeneration Time
set in program step #6.

Meter Immediate

Setting: [ 7 - - 2 ]

The control regenerates immediately when the available volume of softened water drops to 0.

Meter Delayed

Setting: [ 7 - - 3 ]

The control regenerates on the day the available volume of softened water drops to less than the reserve
volume. Regeneration starts at the Regeneration Time set in program step #6.

Meter Delayed - Variable Brining

Setting: [ 7 - - 4 ]

The control regenerates on the day that the available volume of softened water drops to or below the reserve
volume. Regeneration starts at the Regeneration Time set in program step #6. With the variable brining
option activated, the time setting for Cycle 1 is automatically calculated based on the volume of treated water
at the time of regeneration. Cycle time 1 will not exceed the original time setting and is never less than one (1)
minute.

Piston / CAM Type

Regeneration Types Available

dF

[ 7 - - 1 ], [ 7 - - 2 ], [ 7 - - 3 ]

dFFF

[ 7 - - 1 ], [ 7 - - 3 ], [ 7 - - 4 ]

Fltr

[ 7 - - 1 ]

Default

dF

[ 7 - - 3 ]