7000 Master Programming Mode

Page 6

6.

Regeneration Time (No display Code)

NOTE: This program step is not available for Regeneration Type Meter Immediate [ 7 - - 2 ].

Use this program step to set the Time of Day a Regeneration occurs. A non-flashing colon between the hour
and minute digits identifies the Regeneration Time display.

Example:

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button to proceed to the next step.

NOTE: When the piston type is Fltr, Regeneration time defaults to:

— 12:00 A.M., US
— 00:00, metric

7.

Regeneration Day Override (Display code A)

Use this program step, identified by the letter A in the first digit, to set the maximum number of days the unit
can be In Service without a regeneration.

— For Regeneration Type Time Clock Delayed [ 7 - - 1 ], the system regenerates at the time set in program

step #5 after the number of days programmed in this step.

— For any Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ], the system regenerates after the number

of days programmed in this step at the Regeneration Time setting, step #6.

Example:

— Use the Set Up and Set Down buttons to adjust this value.

— Press the Extra Cycle button to proceed to the next step.

Range =

12:00 – 11:59 P.M., US

Range =

00:00 – 23:59, metric

2 o’clock A.M. regeneration time

Setting: [ 2:00 ]

Default =

2:00 A.M.

Range =

0 – 199, Time Clock Delayed [ 7 - - 1 ]

Range =

1 – 199, Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ]

Default =

7 days, Time Clock Delayed [ 7 - - 1 ]

Default =

Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ]

Override every 7 days

Setting: [ A -- 7 ]

Option turned off

Setting: [ A OFF ]