Figure 4, Braukman air vent installation – Hydrotech 5600 SXT Valve Chem Free Iron Filter Operation Manual User Manual

Page 9

background image

7

7.

Make sure the bypass valve is in the service position.

8.

Plug the 24-volt transformer into a 120 VAC 60 Hz outlet. This valve has four positions: 1) Backwash 2) Brine/Rinse
(not used) 3) Rapid Rinse and 4) Brine Refill (not used). When the valve is in the Service position, the extra cycle
button (far left button as shown on Figure 5) must be pressed and held for 5 seconds before it activates. Press and
hold the extra cycle button for 5 seconds to advance the valve to the “1” Backwash position. Slowly turn on the
water supply and allow the unit to backwash until the air purges out of the tank and clears the system.

NOTE: During the initial backwashings, a small amount of fine brownish media may be observed in the drain water.
This is normal and beneficial for the efficient operation of your filter system.

9.

Press the extra cycle button to advance the valve back into the service position indicated by the red dot in upper left
corner of the display.

10. To adjust the Mazzei injector: (Figure 4)

a. Make sure the liter meter is in a vertical position.
b. Adjust air suction by opening and closing the bypass

valve.

c. Setting is correct when the liter meter shows 1/2 L/M of

air entering the injector.

11. Make certain bypass is closed and inlet and outlet valves

are fully opened. Check for leaks.

12. Set the time of day and backwash frequency.

NOTE: Due to the nature of the media, the filter sometimes
takes several days after start-up to completely remove the
iron. Do not become alarmed if this occurs.

Mazzei Injector

Outlet

Inlet

Mixer

Bypass Valve

Figure 4

1. Air Release Cap must be loose or removed to allow air to escape from vent.
2. Vent Bushing 1/2” x 1/8”
3. To opening on side of retention tank (approximately 1/2 way up, from bottom of tank)
4. 3/4” x 3/4” x 1/2” copper tee
5. 3/4” adapter with bushing to tank

Braukman Air Vent Installation

NOTE: The Braukman air vent is not approved for use in the State of Wisconsin. An approved air to water tank and/or
air vent should be used with this application in the State of Wisconsin.
The Braukman Air Vent must be installed at the highest point of the plumbing, between the pressure tank and filter (see Fig. 5).
Please note that the Braukman Air Vent (A) is mounted on a four to six inch pipe extension (B) at the elbow (C) of the highest
point. This enables the vent to better collect any excess air created by the hydrocharger.

To use the Braukman Air Vent on an air-to-water pressure tank, install it approximately halfway up the side of the tank, as shown
in the detailed drawing below.

OPEN

CLOSED

1

2

4

3

Figure 5A

Figure 5B

A

Braukman
Air Vent

Braukman
Air Vent

Pressure

Tank

(Diaphragm)

Pressure

Tank

(Air to Water)

See
Figure
6

B

C

A

B

C

Out

In

Out

In

5

Figure 6