FACTS TO REMEMBER WHEN PLANNING YOUR INSTALLATION
1. All installation procedures must conform to local and state plumbing codes.
2. All water must pass through the hydro-charger, pressure tank and the filter, or refer to the special instructions for a
split-stream installation (System may malfunction if this instruction is ignored.)
3. If lawn sprinkling, a swimming pool, geothermal heating/cooling or water for other devices/activities are to be treated
by the filter, a larger model filter must be selected to accommodate the higher flow rate demands of these items. The
pumping rate of the well pump must be sufficient to accommodate these items plus the backwashing requirement of
the filter. Consult your dealer for alternative instructions if the pumping rate is insufficient.
4. Remember that the filter inlet is attached to the pipe that supplies water (i.e., runs to the pump) and the outlet is the
line that runs toward the water heater.
5. Before commencing the installation it is advisable to study the existing piping system and to determine the size, num-
ber and type of fittings required. Typical system schematics shown in these instructions (Figs. 1, 2 or 3) will be of
assistance. NOTE: If the plumbing system is used as the ground leg of the electric supply, continuity should be main-
tained by installing ground straps around any non conductive plastic piping used in installation.
Section 3: Installation
PROPER INSTALLATION SEQUENCE OF WATER CONDITIONING EQUIPMENT IS VERY
IMPORTANT. REFER TO THE DIAGRAM FOLLOWING FOR YOUR PARTICULAR WATER
SUPPLY.
FIG 1: STANDARD
INSTALLATION
RAW WELL
WATER
RAW
WELL
WATER
RAW WELL
WATER
METER
HYDRO-CHARGER
HYDRO-
CHARGER
TO 110V
OUTLET
TO 110V
OUTLET
SOLENOID
VALVE
SOLENOID
VALVE
(45-60 PSI)
PRESSURE
SWITCH
HYDRO-CHARGER
PRESSURE
SWITCH
SECONDARY
PRESSURE SWITCH
PRIMARY
PRESSURE SWITCH
PRESSURE
TANK
PRESSURE
TANK
SECONDARY
PRESSURE
TANK
PRIMARY
PRESSURE
TANK
TO PUMP
CONTROLLER
TO PUMP
CONTROLLER
RAW WATER
TO OUTDOORS
RAW WATER
TO OUTDOORS
AIR VOLUME CONTROL
(FOR AIR TO WATER
TANKS ONLY)
AIR VOLUME
CONTROL (FOR
AIR TO WATER
TANKS ONLY)
AIR VOLUME CON-
TROL (FOR AIR TO
WATER TANKS ONLY)
MacCLEAN
FILTER
MacCLEAN
FILTER
MacCLEAN
FILTER
SOFTENER
SOFTENER
SOFTENER
IRON FREE WATER
IRON FREE WATER
IRON FREE WATER
IRON FREE
SOFT WATER
IRON
FREE
SOFT
WATER
IRON FREE
SOFT
WATER
AIR RELEASE
VALVE
AIR RELEASE
VALVE
AIR RELEASE
VALVE
FIG 2: SPLIT-STREAM
INSTALLATION
FIG 3:
PUBLIC
WATER
SUPPLY
INSTALLATION
(20-40 PSI)