Scaleless stack distributor, Control operation during regeneration, Control operation during programming – Hydrotech SL948-10-5600 Residential Scaleless System User Manual
Page 3: Time clock delayed control, Startup procedure

2
In normal operation, the Time of Day display will alternate being viewed with the Days Remaining Display the day Volume
Remaining display will count down from a maximum value to zero or (---). Once this occurs, a regeneration cycle will be
initiated at the Set Regeneration Time.
Example
3 days remaining for filter
to
regenerate
0 days Remaining
to Regeneration
Control Operation During Regeneration
In regeneration, the control will display a special regeneration display. In this display, the control will show the current
regeneration step number the valve is advancing to or has reached and the time remaining in that step. The step number
displayed will flash until the valve has completed driving into this regeneration step position. Once all regeneration steps
have been completed, the valve will return to Service and resume normal operation.
Example
Less than 6 minutes
remaining in Regen
Step Rapid Rinse
Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step
position and resume normal step timing.
Control Operation During Programming
The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will
continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored
in memory permanently, eliminating the need for battery back-up power.
Time Clock Delayed Control
A Time Clock Delayed Control regenerates the system on a timed interval. The control will initiate a regeneration cycle
at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day
override value.
5
PM Indicator
PM Indicator
Flow Indicator
(Flashing with water flow)
Flow Indicator
(Flashing with water flow)
Riser Tube
To fit between the con-
trol valve and Scaleless
Stack Distributor
Scaleless Stack
Media
eg Granular
Activated Carbon
Underbed
Startup Procedure
1. Manually Generate the Control Valve to
Backwash model
2. Turn on the water supply slowly to only
half way and let the tank fill with water for
10 minutes
3. Turn off the main water supply and wait
for 3 minutes
4. Turn on the main water supply slowly to
fully open and backwash for 30 minutes
5. Put unit to Rapid Rinse for 5 minutes.
6. Unit is ready to use.
Scaleless Stack Distributor
Riser Tube
Control Valve
Scaleless Stack part #
Model #
Part #
SL948-10-5600
33506
SL1054-12-5600
33507
SL1252-16-7000
33508
The scaleless stack is recommended to be replaced every three years.