Scaleless stack distributor, Control operation during regeneration, Control operation during programming – Hydrotech SL948-10-5600 Residential Scaleless System User Manual

Page 3: Time clock delayed control, Startup procedure

background image

2

In normal operation, the Time of Day display will alternate being viewed with the Days Remaining Display the day Volume

Remaining display will count down from a maximum value to zero or (---). Once this occurs, a regeneration cycle will be

initiated at the Set Regeneration Time.

Example

3 days remaining for filter

to

regenerate

0 days Remaining

to Regeneration

Control Operation During Regeneration

In regeneration, the control will display a special regeneration display. In this display, the control will show the current

regeneration step number the valve is advancing to or has reached and the time remaining in that step. The step number

displayed will flash until the valve has completed driving into this regeneration step position. Once all regeneration steps

have been completed, the valve will return to Service and resume normal operation.

Example

Less than 6 minutes

remaining in Regen

Step Rapid Rinse

Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step

position and resume normal step timing.

Control Operation During Programming

The control will only enter the Program Mode with the valve in Service. While in the Program Mode, the control will

continue to operate normally, monitoring water usage and keeping all displays up to date. Control programming is stored

in memory permanently, eliminating the need for battery back-up power.

Time Clock Delayed Control

A Time Clock Delayed Control regenerates the system on a timed interval. The control will initiate a regeneration cycle

at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day

override value.

5

PM Indicator

PM Indicator

Flow Indicator

(Flashing with water flow)

Flow Indicator

(Flashing with water flow)

Riser Tube

To fit between the con-

trol valve and Scaleless

Stack Distributor

Scaleless Stack

Media

eg Granular

Activated Carbon

Underbed

Startup Procedure

1. Manually Generate the Control Valve to

Backwash model

2. Turn on the water supply slowly to only

half way and let the tank fill with water for

10 minutes

3. Turn off the main water supply and wait

for 3 minutes

4. Turn on the main water supply slowly to

fully open and backwash for 30 minutes

5. Put unit to Rapid Rinse for 5 minutes.
6. Unit is ready to use.

Scaleless Stack Distributor

Riser Tube

Control Valve

Scaleless Stack part #

Model #

Part #

SL948-10-5600

33506

SL1054-12-5600

33507

SL1252-16-7000

33508

The scaleless stack is recommended to be replaced every three years.