Hardware Specifications
Fibre Channel Interface
•
Single independent FC port
•
8-Gigabit FC data-transfer rates
•
1600 MB/sec. maximum full-duplex throughput
•
Supports all FC topologies; fabric, arbitrated loop and point-to-point
•
ANSI Fibre Channel: FC-FS, FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
•
Flash ROM for easy field upgrades
•
FC Class 3 Support
•
Local management and diagnostics
•
Buffer Credits: 41
•
Advanced Data Streaming (ADS
TM
) Technology
Advanced FC Capabilities
•
Supports SNIA HBA API
•
Supports Windows FDMI and WMI
•
Supports Target and Initiator modes
•
Backward compatible with 4-Gb and 2-Gb Fibre Channel
Host Bus Specifications
•
x8 mechanical and x8 electrical PCI Express 2.0 interconnect
•
Supports PCI Express Base Spec 2.0
•
Supports PCI Express CEM Spec 2.0
•
PCI Hot Plug spec 1.0
External Connectivity
•
Easy-to-install full height connection bracket; low-profile bracket included in Finished Goods packaging
•
External LEDs for on-line and speed status for each channel
•
Single (1) pluggable 8Gb optical LC SFP+ module included
Software Specifications
Driver Support
•
Windows Server 2003, 2008, XP, Vista, 7
•
Red Hat Linux ( 2.6 kernel)
•
SUSE Linux (2.6 kernel)
•
Fedora Linux (7 & 8)
•
Mac OS X (10.4.x - 10.6.x)
•
VMware ESX Server 3.5
Agency Approvals
Safety and Environmental
•
FCC Part 15, Subpart B, Class B
•
EN55022: 2006, Class B
•
EN55024: 1998A + A1: 2001 & A2: 2003
•
EN60950-1: 2001
•
EN60825-1: 1994-2: 2004
Environmental & Physical Specifications
Dimensions
•
Conforms to PCI Express Low Profile form-factor specs
•
Length 6.600”
•
Height
2.731”
Operating Environment
•
Temperature: 0-40° C
•
Humidity: 10 - 90% non-condensing
Storage Environment
•
Temperature: -40°-70°C (-40°-157°F)
•
Humidity: 5 - 95% non-condensing
Power
•
5.3W (Typical)
Airflow
•
100 lf/m (min) recommended
Optical Cabling
•
50/125µm up to 50m @ 8-Gb
•
50/125µm up to 150m @ 4-Gb
•
50/125µm up to 300m @ 2-Gb
Ordering Information
Model Number
•
CTFC-81EN-000
RoHS Compliant
Yes
Celerity FC-81EN
Host Adapter
Celerity FC-81EN