M c c - 1, Har-1, Hf-1 – Green Air Products MCC-1 User Manual
Page 2: Hr-1, Icro, Limate, Ontroller, Unction, Elays
The MicroClimate Controller MCC-1
is designed to perform all the major
atmospheric and timed functions re-
quired in an automated growth envi-
ronment including temperature, humid-
ity, carbon dioxide enrichment, light-
ing and irrigation control. The control-
ler incorporates an external coil cool-
ing thermostat , a dehumidifying humi-
distat, a 24-hour clock timer, a photo-
sensor and a repeat cycle timer. Heating
and humidifying control is provided by
triggers for remote high-amperage re-
lays which enable synchronized equip-
ment management. Automatic override
and defeat systems coordinate controls
to consider all possible variables. The
MCC-1 is enclosed in a black anodized, brush finish aluminum housing. An attractive
screen-printed front panel with function indicator lights makes system monitoring and
adjustment quick and easy. All connections are standard 3-prong grounded plugs and
receptacles. No hard wiring is required for basic operations. Low and high voltage relays
are available to operate auxiliary equipment. Every aspect of the growing environment may
be addressed by the Micro Climate Controller (MCC-1). Operates on 115VAC with 12 Amp
switching capacity. Approved for indoor only.
M
ICRO
C
LIMATE
C
ONTROLLER
Pumps
or
Solenoid Valves
CO
2
Equipment
or
Irrigation
Intake and/or
Exhaust Fan
Heating
110 V
Outlet
Lighting
5s
23
3.5m
17
30
15
5
15
21
7m
15m
1
2
5
6
7
8
10
3
Exhaust On
Temperature High
Humidity High
Timed Outlet
CO
2
Outlet
Cycle Outlet
Heater Relay
Humidifing Relay
Climate Controller
Thermostat
Humidistat
Sequence Timer
Exhaust
Outlet
HF-1
Relay
HR-1
Relay
CDDS-1
Trigger
On Timed
Outlet
Off Timed
Outlet
CO2
Outlet
Cycle
Timer
Outlet
DURATION
Of "ON" Time
FREQUENCY
Of "ON" Time
24 Hour Timer
OFF
Photo Sensor
Cycle
Timer
CO2
Timer
AT M O S P H E R I C S Y S T E M S & C O N T R O L S
G
REEN
A
IR
P
RODUCTS
MCC-1
MANUFACTURED BY GREEN AIR PRODUCTS , USA 110VAC 15A MAX
Temperature
F
UNCTION
R
ELAYS
Dry Contact Switches
M C C - 1
The HAR-1 is a power relay that uses high
amperage capacity contacts to transfer power
to large fans or lighting systems requiring
high voltage or amperage service. Use to
operate 115 or 240 Volt high draw equip-
ment. 30 Amp switching capacity with 115
Volt trigger.
HAR-1
Thie HF-1 is a high amperage relay with a
built in humidifying humidistat. Use to
supply 115 or 240 Volt power to humidify-
ing equipment when humidity falls below set
point. 30 Amp switching capacity for heavy
load requirements.
HF-1
The HR-1 is a high amperage relay with a
built in external coil heating thermostat.
Use to supply 115 or 240 Volt power to
heating equipment when tempeature falls
below set point. 30 Amp switching capacity
for heavy load requirements. A jack
receptical and internal low voltage dry con-
tacts are used to function gas type heaters.
See MCC-1 installation description.
HR-1