4.1

ACCEPTANCE TEST :
These acceptance tests ensure that the unit is in working
order after shipping. These tests may also be used to
verify basic operation when the unit has been restored
to normal use after prolonged storage.

4.2

VARIABLE OUTPUT SECTIONS

4.2.1

CONSTANT VOLTAGE MODE :

a)

Ensure that the AC power switch is in the OFF position.

b)

Connect the unit to a rated power source.

c)

Turn the voltage and current controls fully counter
clockwise.

d)

Connect a digital voltmeter (DVM) to the output
terminals, observing correct polarirty. The DVM must be
rated better than 0.5% accuracy.

e)

Turn the power switch ON. The front panel digital meters
will light up and voltmeter and ammmeter displays will
read zero.

f)

Turn the current control a 1/2 turn clockwise. Slowly turn
the voltage control clockwise and observe both the front
panel voltmeter and the DVM.

g)

Compare the DVM reading with the front panel
voltmeter reading. The control range will be from 0 to
32V. The green voltage mode LED will be illuminated to
indicate CV mode of operation.

4.2.2

CONSTANT CURRENT MODE :

a)

Ensure that the AC power switch is in the OFF position.

b)

Connect the unit to a rated power source.

4

PCB Components

ZSDT-CT/05 PCB

=======================================================================

Ref Designator

Value

=======================================================================

C24

10µF/50V, ELE

C25

10µF/50V, ELE

C26

0.1µF/50V, CD

C27

470µF/50V, ELE

C29

1000µF/35V,ELE

DIODES

CR1

Not Used

CR2

1N4007, 1KV/1A

CR3

1N4007, 1KV/1A

CR4

1N4007, 1KV/1A

CR5

1N4007, 1KV/1A

CR6

1N4007, 1KV/1A

CR7

1N4007, 1KV/1A

CR8

1N4007, 1KV/1A

CR9

1N4007, 1KV/1A

C10

1N4007, 1KV/1A

CR11

1N4007, 1KV/1A

CR12

1N4007,1KV/1A.

CR13

1N4007,1KV/1A.

CR14

1N4007,1KV/1A

CR15

1N4007,1KV/1A

CR16

1N4007, 1KV/1A

CR17

1N4007, 1KV/1A

CR18

1N4007, 1KV/1A

CR19

1N4007, 1KV/1A

CR20

1N4007, 1KV/1A

CR21

1N4007, 1KV/1A

CR22

1N4007, 1KV/1A