beautypg.com

Global Specialties 4005 - Manual User Manual

Page 10

background image

10

3. OPERATION

3-1. Controls, Indicators and Connectors

Figure 1.

FRONT

PANEL OPERATOR’S CONTROLS

POWER SWITCH:

Push for Power On/Off

RANGE SWITCHES:

Frequency Range Selector

FUNCTION SWITCHES:

Select Sine wave, Triangle Wave or

Square Wave Output

ATTENUATOR:

Selects Output Level by -20 dB.

INTERNAL/EXTERNAL SWITCH:

IN: for External Frequency Counter

OUT: for Internal Frequency Counter.

LOW PASS FILTER:

With this switch pushed in, the input is routed through a
SWITCH (LPF) low- pass filter with-3dB point of
approximately 100KHz.

DISPLAY:

6 Digit (0.4") Green 7 segment display .

GATE TIME INDICATOR:

Gate Time is selected automatically by

the input signal.

MHz, KHz, Hz, mHz INDICATOR:

Indicates Unit of Frequency.

COARSE FREQUENCY DIAL:

Controls the output coarse frequency in

the selected range.