beautypg.com

American Dryer Corp. MLS-460 User Manual

Page 19

background image

15

c. Annunciator, Pendent, Over-Burner, and RTD (Resistive Temperature Device) Cable

Remove the four (4) bolts that hold on the character (460) panel. Open the door to the main electrical

enclosure, the female end of the RTD (Resistive Temperature Device) cable will be found there. Loosen

the 1-inch lock nut and remove the modified hole seal. Put the female end of the RTD cable through the

hole in the top of the electrical enclosure. Connect the male end and the female end of the RTD cable

together, pull the cable up until the threads of the reducing bushing can be seen through the hole into

where the character (460) panel was. Next, get the 1-inch lock nut on by a few threads, slip the modified

hole seal under the lock nut holding the 45° cord grip connector, then tighten the 1-inch lock nut. Replace

the character (460) panel and tighten the four (4) bolts.