beautypg.com

GeoVision ML200SLD User Manual

Page 3

background image

May 13, 2011

5

3. On the Web interface of the GV-AS400, select Input Setting, and select an input type

and input function for the connected sensor from the electric bolt.

Input Type

Input Function

4. On the Web interface of the GV-AS400, select Output Setting, and select an output type

and output function for the connected electric bolt.

For details on configuring the input and out devices, see 3.4.3.D Input Function and 3.4.3.E

Output Function on the GV-AS Controller User’s Manual.


















May 13, 2011

6

Specifications

Voltage

DC 12V or AC 24V

Current

0.9A (start); 0.3A (standby)

Lock Sensor Switch Rating

1A at AC/DC 30V

Door Status Sensor Switch Rating

0.5A at AC/DC 30V (magnetic reed switch)

Auto Relock Jumper

0, 2.5 and 5 seconds (adjustable)

Dimension (L x W x H)

202 x 35 x 43 mm / 7.95 x 1.38 x 1.69 in

Weight

0.9 kg / 1.98 lb

Certification

CE and UL