GeoVision ML200SLD User Manual
Page 3

May 13, 2011
5
3. On the Web interface of the GV-AS400, select Input Setting, and select an input type
and input function for the connected sensor from the electric bolt.
Input Type
Input Function
4. On the Web interface of the GV-AS400, select Output Setting, and select an output type
and output function for the connected electric bolt.
For details on configuring the input and out devices, see 3.4.3.D Input Function and 3.4.3.E
Output Function on the GV-AS Controller User’s Manual.
May 13, 2011
6
Specifications
Voltage
DC 12V or AC 24V
Current
0.9A (start); 0.3A (standby)
Lock Sensor Switch Rating
1A at AC/DC 30V
Door Status Sensor Switch Rating
0.5A at AC/DC 30V (magnetic reed switch)
Auto Relock Jumper
0, 2.5 and 5 seconds (adjustable)
Dimension (L x W x H)
202 x 35 x 43 mm / 7.95 x 1.38 x 1.69 in
Weight
0.9 kg / 1.98 lb
Certification
CE and UL