Stopping, Trouble shooting, Pump will not run – BJM Pumps XP-SKX150CSS User Manual
Page 9: Pump runs but does not deliver rated capacity, Servicing your submersible pump, Maintaining your pump
9
Consult EIM ELELCTRIC Co., LTD. Instruction Manual for Installation, Operation
and Maintenance before connecting, operating or conducting maintenance on the
Explosion Proof Submersible Motor.
STOPPING
To stop the pump (manual and automatic mode) turn off the breaker, or turn the
electrical power source off (generator).
TROUBLE SHOOTING
Disconnect the electrical power source to the pump BEFORE
attempting any type of trouble shooting, service or repair.
PUMP WILL NOT RUN
Refer to EIM ELECTRIC CO., LTD Instruction Manual for Installation, Operation and
Maintenance for the Explosion Proof Submersible Motors (EMQY Series; FM Approved
for Class I, Division 1, Group C & D).
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY
1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe.
2. Worn impeller and/or suction cover. Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped being too thick.
4. Pumping air. Check liquid level and position of pump.
5. Excessive voltage drops due to long cables.
6. Pump running backwards, check rotation.
SERVICING YOUR SUBMERSIBLE PUMP
Pump should be disconnected from the electric power supply before proceeding to do
any service or maintenance.
Service on submersible electric motor should only be performed by a qualified
electrician. Refer to EIM ELECTRIC CO., LTD Instruction Manual for Installation,
Operation and Maintenance for the Explosion Proof Submersible Motors (EMQY Series;
FM Approved for Class I, Division 1, Group C & D).
MAINTAINING YOUR PUMP
Pump should be disconnected from the electric power supply before proceeding
to do any service or maintenance.
Pump should be inspected at regular intervals.