Changing seal oil – BJM Pumps XP-SKX150CSS User Manual
Page 10
10
More frequent inspections are required if the pump is used in a harsh
environment.
Preventative maintenance should be performed to reduce the chance of
premature failure.
Worn impellers and lip seals should be replaced.
Cut or cracked power cords must be replaced. (Never operate a pump with a
cut, cracked or damaged power cord.)
Maintenance should always be done when taking a pump out of service before
storage.
The impeller to suction cover clearance should be adjusted to between 0.01” to
0.02” for optimal cutting of the shredder. Shim kits are available if adjustment is
required.
1) Clean pump of dirt and other build up.
2) Check condition of oil around the shaft seals.
3) Check hydraulic parts: check for wear.
4) Inspect power cable. Make sure that it is free of nicks or cuts.
CHANGING SEAL OIL
Refer to EIM ELECTRIC CO., LTD Instruction Manual for Installation, Operation and
Maintenance for the Explosion Proof Submersible Motors (EMQY Series; FM Approved
for Class I, Division 1, Group C & D).