Troubleshooting, Order replacement battery, Model be525-rs – American Power Conversion UPS User Manual

Page 2

background image

Troubleshooting

Use the table below to solve minor Back-UPS ES installation or operation problems. Consult APC Online Technical Support or call APC
Technical Support for assistance with problems that cannot be resolved using the table below:

Back-UPS ES will not turn on.

No power available at the Surge Protection
outlet.

Connected equipment loses power.

The Status indicator is lit (amber) and the
Back-UPS ES is beeping four times every 30
seconds.

The Status indicator flashes (amber) once
per second and the Back-UPS ES beeps
once per second at the same time.

Inadequate runtime.

Battery is disconnected and utility power is not available at
the wall outlet.

Surge Protection outlet has been overloaded.

Utility power not available at the wall outlet.

Equipment is connected to the “Surge Protection” outlet.

The Back-UPS ES is overloaded.

The PowerChute Personal Edition software has performed
a shutdown due to a power failure.

The Back-UPS ES has exhausted its available battery
power.

Connected equipment does not accept the step-
approximated sine waveform the Back-UPS ES.

The Back-UPS ES may require service.

The Back-UPS ES is operating on battery.

Battery capacity is low (about 2 minutes of use remaining).

The battery is not fully charged.

Battery is near the end of useful life.

Connect the battery (see Battery Replacement) and ensure power is available at the
wall outlet.

Move equipment plugged into Surge Protection outlet to Battery Backup plus Surge
Protection outet.
Ensure that the fuse or circuit breaker for the outlet is not tripped, and that the wall
switch controlling the outlet (if any) is in the ON position.

Ensure that the equipment you want to stay powered during a power failure is
plugged into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge
Protection” outlet.

Make sure the equipment plugged into the outlets of the unit are not overloading the
capacity of the unit. Try disconnecting some of the equipment and see if the problem
continues.

The Back-UPS ES is operating normally.

The Back-UPS ES can only operate on battery power for a limited amount of time.
The unit will eventually turn off when the available battery power has been used.
Allow the unit to recharge for 5 hours before continuing use of the unit.

The output waveform is designed for computers and computer-related equipment. It
is not designed for use with motor-type equipment.

Contact APC Technical Support for further troubleshooting.

The Back-UPS ES is operating normally and using battery power. Once On Battery,
you should save your current work, power down your equipment, and turn the unit
OFF. Once normal power is restored, you may turn the unit back ON and power your
equipment.

The Back-UPS ES is about to shut off due to a low battery charge condition! When
the unit beeps once every second, the battery has about 2 minutes of power
remaining. Immediately power down your computer and turn the unit OFF. When
normal power returns, the unit will recharge the battery.
Allow the unit to charge by leaving it plugged into the wall at least 16 hours.

As a battery ages, the amount of runtime available will decrease. You can replace
the battery by ordering one at www.apc.com/ru. Batteries also age prematurely if the
Back-UPS ES is placed near excessive heat.

Problem

Probable Cause

Solution

Specifications

Warranty

Service

APC Contact Information

Input

Voltage

230 V AC Nominal

Frequency

47 - 53 Hz

Brownout Transfer

160 V AC, typical

Over-voltage Transfer

280 V AC, typical

Output

Battery Backup with Surge
Capacity (3 outlets)

525 VA / 300 W

Surge Only Capacity (1 outlet)

6 Amps (including UPS output)

Voltage - On Battery

230 V AC + 8%

(step-approximated sine wave)

Transfer Time

5 ms typical, 10 ms maximum

Protection and Filter AC Surge Protection

Full time, 150 joules

Telephone Surge Protection

Single line (2-wire)

EMI/RFI Filter

Full time

AC Input

Resettable circuit breaker

Battery

Type

Sealed, maintenance-free lead acid

Typical Life

3 - 6 years depending on the number of

discharge cycles and environmental temperature

Physical

Net Weight

7.3 kg (16 lb)

Size (UPS only)

12 x 28.5 x 19.7 cm

(4.72” (H) x 11.2” (W) x 7.8” (D))

Operating Temperature

0

o

C to 40

o

C (+32

o

F to 104

o

F)

Storage Temperature

-15

o

C to 45

o

C (+5

o

F to 113

o

F)

Operating Relative Humidity

0 to 95% non-condensing

Operating Elevation

0 to 10,000 ft (0 to 3,000m)

Model

BE525-RS

The standard warranty is 2 years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory-reconditioned unit. Customers
who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with APC Technical Support. APC
will ship the replacement unit once the defective unit is received by the repair
department, or cross-ship upon the provision of a valid credit card number. The
customer pays for shipping to APC. APC pays ground freight transportations costs
back to the customer.

1. Consult the Troubleshooting section to eliminate common problems.

2. Verify the battery is connected (see Battery Replacement) and the Circuit Breaker is
not tripped (see Troubleshooting section).

If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.

3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).

4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.

Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under the warranty (insuring the package for full value is recommended).

5. Write the RMA# on the outside of the package.

6. Return the unit by insured carrier to the address given to you by the APC Technical
Support representative.

Online Technical Support . . . . . . . . . . http://support.apc.com
Web Site . . . . . . . . . . . . . . . . . . . . . . . www.apc.com/ru
Worldwide . . . . . . . . . . . . . . . . . . . . . . +1.800.800.4272
APC Russia: . . . . . . . . . . . . . . . . . . . 7 (095) 916 71 66 Technical Support

7 (095) 929 90 95 Sales Support

Order Replacement Battery

Replace with an APC qualified battery. Replacement batteries can be ordered from
APC Global Services. Have your Back-UPS ES model number available when
ordering. Your model number can be found on the bottom of the unit.