beautypg.com

Flowline LD32‐S4_1 DeltaSpan User Manual

Page 3

background image

Rev B 

MN301040 

3 of 16 

SPECIFICATIONS  

Step Two 

 

Service: 

Compatible liquids 

Wetted Materials: 

Body: 316 SS, 316L SS and 

Buna‐N 

Cable: Polyurethane or ETFE 
Bullet Nose: PVC (LD31 

series only) 

Accuracy: 

±0.25% of full scale 

Temperature Limit:  

0 to 176°F (‐18 to 80°C) 

Compensated 
Temperature Range: 

0 to 176°F (‐18 to 80°C) 

Thermal Effect:  

Less than ±0.02%/°F 

Pressure Limit:  

2X full scale 

Power Requirement:  

10 to 28 VDC 

Output Signal:   

4 to 20 mA DC, 2‐wire 

Response Time: 

50 ms 

Max. Loop Resistance: 

900 ohms 

Electrical Connections: 

Wire pigtail 

Cable Length: 

‐__01/‐__11: 40’ (12.2 m) 
‐__21/‐__31: 60’ (18.3 m) 

Mounting Orientation: 

Suspended in tank below 
level being measured ‐ Can 
be placed on the bottom of 
the tank on its side 

Weight: 

2.2 lb (1.0 kg) – (LD31 
series) 
4.3 lb (2.0 kg) – (LD32 
series) 

Agency Approvals: 

CE, UL Intrinsically Safe to 
UL Standard 913. (See 
Intrinsic Safety Approval 
Classification.) 

 

 
The following standards were used for CE approval: 
 

IEC 61000‐4‐2: 2001 

 

IEC 61000‐4‐3: 2006 

 

IEC 61000‐4‐4: 2004 

 

IEC 61000‐4‐5: 2005 

 

IEC 61000‐4‐6: 2006 

 

IEC 61000‐4‐8: 2001 

 

CENELEC EN 55011: 2003 

 

CENELEC EN 61326: 2003 

 

89/336/EEC EMC Directive 

 
WARNING:  To  prevent  ignition  of  flammable  or 
combustible  atmospheres,  disconnect  power  before 
servicing.    Use  with  approved  safety  barriers  using 
entity evaluation. 
 

Series 

LD31 

LD32 

Vmax 

26 VDC 

28 VDC 

Imax 

93 mA 

93 mA 

Ci 

0.051uF 

0.051 uF 

Li 

240 uH 

240 uH 

Pi 

0.651 W 

0.651 W 

 

WARNING:  Do  not  exceed  specified  supply  voltage 
ratings.  Permanent damage not covered by warranty 
will result.  This device is not designed for 120 or 240 
volt AC operations.  Use only on 10 to 28 VDC. 
 
 

 

Optional Desiccant Filter (LD90‐3000): 

o

For extra protection against humidity we offer the LD90‐3000 desiccant filter that can be attached to 
the vent tube. 

 

 
Optional Cable Hanger (LD90‐S000): 

o

Attach the cable hanger to the ½” thread of the LD31 or LD32 series and 
connect to the loop a chain to provide a secure method for lowering and 
raising the sensor. 

o

The cable hanger is ideal for sumps or wet wells.  

 

 