DE DIETRICH INNOVENS MCA 25_28 BIC User Manual
Page 38
![background image](/manuals/329059/38/background.png)
Code Faults
Cause
of the
fault
Description
Checking / solution
L16
PARASIT FLAME
PCU
Detection of a parasite flame
Ionization current present when there should not
be a flame
Ignition transformer defective
Gas valve defective
The burner remains very hot: CO
2
too high
4
Contact the professional who takes care of
maintenance of the appliance
L17
VALVE FAIL
PCU
Problem on the gas valve
Bad connection
SU PCB faulty
4
Contact the professional who takes care of
maintenance of the appliance
L34
FAN FAILURE
PCU
The fan is not running at the right
speed
Bad connection
Fan defective
4
Contact the professional who takes care of
maintenance of the appliance
L35
BACK>BOIL FAIL
PCU
Flow and return reversed
Bad connection
Sensor fault
4
Contact the professional who takes care of
maintenance of the appliance
Water circulation direction reversed
4
Check the circulation (direction, pump,
valves)
L36
I-CURRENT FAIL
PCU
The flame went out more than 5
times in 24 hours while the burner
was operating
No ionization current
4
Check that the gas valve is fully opened
4
Contact the professional who takes care of
maintenance of the appliance
L37
SU COM.FAIL
PCU
Communication failure with the SU
PCB
Bad connection
4
Contact the professional who takes care of
maintenance of the appliance
L38
PCU COM.FAIL
PCU
Communication failure between the
PCU and SCU PCBs
Bad connection
SCU PCB not connected or faulty
4
Contact the professional who takes care of
maintenance of the appliance
L39
BL OPEN FAIL
PCU
The BL inlet opened for a short time Bad connection
External cause
Parameter incorrectly set
4
Contact the professional who takes care of
maintenance of the appliance
L40
TEST.HRU.FAIL
PCU
HRU/URC unit test error
Bad connection
External cause
Parameter incorrectly set
4
Contact the professional who takes care of
maintenance of the appliance
L250 DEF.WATER MIS.
PCU
The water pressure is too low
Hydraulic circuit incorrectly vented
Water leak
Measurement error
4
Top up with more water if necessary
4
Reset the boiler
L251 MANOMETRE FAIL
PCU
Fault on the water pressure sensor Wiring problem
The manometer is defective
Sensor pcb defective
4
Contact the professional who takes care of
maintenance of the appliance
6. Troubleshooting
MCA 25/28 BIC
37
31/08/2011 - 300024163-001-B