Technical specifications, 7 technical specifications, 1 technical specifications – DE DIETRICH INNOVENS MCA 15 - MCA 25 - MCA 25_28 MI User Manual
Page 40

7 Technical specifications
7.1
Technical specifications
Boiler type
MCA 15
MCA 25
MCA 25/28 MI
General
Flow rate setting
Adjustable
Modulating, Start/Stop, 0 - 10 V
Nominal output (Pn)
Heating System (80/60 °C)
minimum-maximum kW
3,0 - 14,5
5,0 - 24,1
5,0 - 24,1
Factory setting
kW
14,5
24,1
19,4
Nominal output (Pn)
DHW System
minimum-maximum kW
-
-
5,0 - 28,6
Factory setting
kW
-
-
28,6
Data on the gases and combustion gases
Gas consumption - Natural gas H (G20) minimum-maximum m
3
/h
0,33 - 1,59 0,55 - 2,65 0,55 - 2,96
Gas consumption - Propane G31
minimum-maximum m
3
/h
0,13 - 0,61 0,21 - 1,02 0,21 - 1,15
NOx-Emission per year (n =1)
mg/kWh 33
38
38
Characteristics of the heating circuit
Water content
l
1,7
1,7
1,7
Water operating pressure (PMS)
maximum
kPa (bar) 300 (3,0)
300 (3,0)
300 (3,0)
Water temperature
maximum
°C
110
110
110
Operating temperature
maximum
°C
90
90
90
Characteristics of the domestic hot water circuit
Specific hot water flow D (60 °C)
l/min
-
-
8,2
Specific hot water flow D (40 °C)
l/min
-
-
13,7
Flow rate threshold
minimum
l/min
-
-
1,2
Operating pressure (Pmw)
maximum
kPa (bar) -
-
800 (8,0)
Electrical characteristics
Power supply voltage
VAC
230
230
230
Power consumption - Full load
maximum
W
88
116
124
Factory setting
W
53
72
72
Electrical protection index
IPX4D
IPX4D
IPX4D
Other characteristics
Total weight (empty)
kg
43
43
44
Acoustic level at 1 metre at high speed
dBA
35
42
44
7. Technical specifications
MCA 15 - MCA 25 MCA 25/28 MI
39
23/08/2011 - 300024159-001-B